Photo |
Name |
Article |
Price |
|
OGNEZA Fire collar, lock type "Light", red, d 80 [Code number: 1r0147]
Details
|
1r0147 |
474 rub |
|
|
OGNEZA Fire collar, lock type "Light", gray, d 65 [Code number: 1r0148]
Details
|
1r0148 |
420 rub |
|
|
OGNEZA Fire collar, lock type "Light", red, d 65 [Code number: 1r0149]
Details
|
1r0149 |
420 rub |
|
|
OGNEZA Fireproof sound insulation sleeve, d 110/100 (price on request) [Code number: pgz_110_100]
Details
|
pgz_110_100 |
|
Attention! New requirements of JV 30.13330.2016 for the protection of plastic pipes are mandatory from the summer of 2019.
The passage of plastic pipes through ceilings in residential and office buildings should include:
- soundproofing;
- fire protection;
- sealing.
OGNEZA-PGZ is a complex product for fire protection of plastic pipes. It consists of a split metal body, a thermally expanding material, a soundproofing layer of mineral wool and a fireproof sealant for waterproofing.
Characteristics:
- There are no analogues
- Easy installation in 3 movements
- It is possible to manufacture for any thickness of coatings
- All standard sizes
- Fire resistance EI 180
- Reduces noise by at least 30 dB
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
110/100 |
100 |
114 |
176 |
155/185 |
182 |
Installation instructions
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA Fireproof sound insulation sleeve, d 110/200 (price on request) [Code number: pgz_110_200]
Details
|
pgz_110_200 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential and administrative buildings, hotels and shopping centers, apartment buildings, social and medical institutions, as well as railway stations
- To protect premises from fire and smoke
Characteristics:
- It is a complex product, which consists of a metal detachable body, a special material that expands with increasing temperature, a layer of soundproof mineral wool, and a fire sealant;
- Allows you to reduce the cost of installing equipment for fire protection and sound insulation;
- Swelling ratio: not less than 900%;
- Product color: red;
- Fire resistance limit: 180 minutes;
- Operation inertia: no more than 4 minutes.
According to the current regulations, the passages of plastic pipes through the ceilings must be protected from fire, while they must comply with the requirements for sound insulation. And fire-fighting muds of Ogneza PGZ meet the established requirements.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
110/200 |
200 |
114 |
176 |
255/285 |
182 |
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA Fireproof sound insulation sleeve, d 110/250 (price on request) [Code number: pgz_110_250]
Details
|
pgz_110_250 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential and administrative buildings, hotels and shopping centers, apartment buildings, social and medical institutions, as well as railway stations
- To protect premises from fire and smoke
Characteristics:
- It is a complex product, which consists of a metal detachable body, a special material that expands with increasing temperature, a layer of soundproof mineral wool, and a fire sealant;
- Allows you to reduce the cost of installing equipment for fire protection and sound insulation;
- Swelling ratio: not less than 900%;
- Product color: red;
- Fire resistance limit: 180 minutes;
- Operation inertia: no more than 4 minutes.
According to the current regulations, the passages of plastic pipes through the ceilings must be protected from fire, while they must comply with the requirements for sound insulation. And fire-fighting muds of Ogneza PGZ meet the established requirements.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
110/250 |
250 |
114 |
176 |
305/335 |
182 |
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA Fireproof sound insulation sleeve, d 110/300 (price on request) [Code number: pgz_110_300]
Details
|
pgz_110_300 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential and administrative buildings, hotels and shopping centers, apartment buildings, social and medical institutions, as well as railway stations
- To protect premises from fire and smoke
Characteristics:
- It is a complex product, which consists of a metal detachable body, a special material that expands with increasing temperature, a layer of soundproof mineral wool, and a fire sealant;
- Allows you to reduce the cost of installing equipment for fire protection and sound insulation;
- Swelling ratio: not less than 900%;
- Product color: red;
- Fire resistance limit: 180 minutes;
- Operation inertia: no more than 4 minutes.
According to the current regulations, the passages of plastic pipes through the ceilings must be protected from fire, while they must comply with the requirements for sound insulation. And fire-fighting muds of Ogneza PGZ meet the established requirements.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
110/300 |
300 |
114 |
176 |
355/385 |
182 |
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA Fireproof sound insulation sleeve, d 50/100 (price on request) [Code number: pgz_50_100]
Details
|
pgz_50_100 |
|
Attention! New requirements of JV 30.13330.2016 for the protection of plastic pipes are mandatory from the summer of 2019.
The passage of plastic pipes through ceilings in residential and office buildings should include:
- soundproofing;
- fire protection;
- sealing.
OGNEZA-PGZ is a complex product for fire protection of plastic pipes. It consists of a split metal body, a thermally expanding material, a soundproofing layer of mineral wool and a fireproof sealant for waterproofing.
Characteristics:
- There are no analogues
- Easy installation in 3 movements
- It is possible to manufacture for any thickness of coatings
- All standard sizes
- Fire resistance EI 180
- Reduces noise by at least 30 dB
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
50/100 |
100 |
54 |
116 |
155/185 |
122 |
Installation instructions
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA Fireproof sound insulation sleeve, d 50/250 (price on request) [Code number: pgz_50_250]
Details
|
pgz_50_250 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential and administrative buildings, hotels and shopping centers, apartment buildings, social and medical institutions, as well as railway stations
- To protect premises from fire and smoke
Characteristics:
- It is a complex product, which consists of a metal detachable body, a special material that expands with increasing temperature, a layer of soundproof mineral wool, and a fire sealant;
- Allows you to reduce the cost of installing equipment for fire protection and sound insulation;
- Swelling ratio: not less than 900%;
- Product color: red;
- Fire resistance limit: 180 minutes;
- Operation inertia: no more than 4 minutes.
According to the current regulations, the passages of plastic pipes through the ceilings must be protected from fire, while they must comply with the requirements for sound insulation. And fire-fighting muds of Ogneza PGZ meet the established requirements.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Slab Thickness |
Inner diameter |
Outside Diameter |
Height for finishing / monolith |
Through hole diameter (not less than) |
|
mm |
mm |
mm |
mm |
mm |
50/250 |
250 |
54 |
116 |
305/335 |
122 |
Download product installation manual: OGNEZA Fireproof sound insulation sleeve
|
|
OGNEZA PGZ-M Fireproof sound insulation sleeve, d 110/200 (price on request) [Code number: pgz_m_110_200]
Details
|
pgz_m_110_200 |
|
|
|
OGNEZA PGZ-M Fireproof sound insulation sleeve, d 110/250 (price on request) [Code number: pgz_m_110_250]
Details
|
pgz_m_110_250 |
|
|
|
OGNEZA Fire collar, lock type "Light", d 110/108 (price on request) [Code number: pm_110_108_light]
Details
|
pm_110_108_light |
|
Application purposes:
- For preventing the spread of fire and combustion products through ceilings and walls
Characteristics:
- Housing consists of two parts, detachable
- High fire resistance - EI-180
- Products are certified
- Metal parts are painted with powder paint which increases the corrosion resistance
- Easy assembly/disassembly
- Coefficient of expansion is not less than 900%
- Collar is triggered at 15 seconds at temperature of +150 °C, complete overlap occurs at the intersection at 4 minute
- Keeps characteristics at temperatures from -50 °C to +80 °C
- 30 years lifetime
- Light type
Inner diameter: DN 110/108
Color: light gray
Download installation instruction: OGNEZA Fire collar
|
|
OGNEZA Fire prevention symmetrical sleeve, d 110, d1 150 (price on request) [Code number: pm_110_150]
Details
|
pm_110_150 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential (including multi-apartment) buildings, hotels and hostels, social and medical institutions, shopping centers, airports and railway stations, industrial enterprises, etc
- To protect premises from fire and smoke
Characteristics:
- It is an elongated fire sleeve equipped with two liners made of thermally expandable material (one on each side);
- Provides double fire protection - just one sleeve is enough for the length of the entire ceiling;
- The body is detachable, there is a tie-lock, so that the symmetrical fire coupling can be used on already installed pipelines;
- Metal parts are powder coated for corrosion protection;
- The clutch begins to work already at the 15th second when the temperature rises to +150 ° C, the complete overlap of the assembly occurs at the fourth minute;
- Swelling ratio: not less than 900%;
- Product color: grey;
- Fire resistance limit: 180 minutes;
- Service life: 30 years.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Outside diameter |
Through Hole Diameter (minimum) |
Inner diameter |
Length |
Insert thickness |
|
mm |
mm |
mm |
mm |
mm |
PM-110 |
125 |
128 |
110 |
300 |
7 |
|
|
OGNEZA Fire prevention symmetrical sleeve, d 110, d1 200 (price on request) [Code number: pm_110_200]
Details
|
pm_110_200 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential (including multi-apartment) buildings, hotels and hostels, social and medical institutions, shopping centers, airports and railway stations, industrial enterprises, etc
- To protect premises from fire and smoke
Characteristics:
- It is an elongated fire sleeve equipped with two liners made of thermally expandable material (one on each side);
- Provides double fire protection - just one sleeve is enough for the length of the entire ceiling;
- The body is detachable, there is a tie-lock, so that the symmetrical fire coupling can be used on already installed pipelines;
- Metal parts are powder coated for corrosion protection;
- The clutch begins to work already at the 15th second when the temperature rises to +150 ° C, the complete overlap of the assembly occurs at the fourth minute;
- Swelling ratio: not less than 900%;
- Product color: grey;
- Fire resistance limit: 180 minutes;
- Service life: 30 years.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Outside diameter |
Through Hole Diameter (minimum) |
Inner diameter |
Length |
Insert thickness |
|
mm |
mm |
mm |
mm |
mm |
PM-110 |
125 |
128 |
110 |
200 |
7 |
|
|
OGNEZA Fire prevention symmetrical sleeve, d 110, d1 250 (price on request) [Code number: pm_110_250]
Details
|
pm_110_250 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential (including multi-apartment) buildings, hotels and hostels, social and medical institutions, shopping centers, airports and railway stations, industrial enterprises, etc
- To protect premises from fire and smoke
Characteristics:
- It is an elongated fire sleeve equipped with two liners made of thermally expandable material (one on each side);
- Provides double fire protection - just one sleeve is enough for the length of the entire ceiling;
- The body is detachable, there is a tie-lock, so that the symmetrical fire coupling can be used on already installed pipelines;
- Metal parts are powder coated for corrosion protection;
- The clutch begins to work already at the 15th second when the temperature rises to +150 ° C, the complete overlap of the assembly occurs at the fourth minute;
- Swelling ratio: not less than 900%;
- Product color: grey;
- Fire resistance limit: 180 minutes;
- Service life: 30 years.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Outside diameter |
Through Hole Diameter (minimum) |
Inner diameter |
Length |
Insert thickness |
|
mm |
mm |
mm |
mm |
mm |
PM-110 |
125 |
128 |
110 |
250 |
7 |
|
|
OGNEZA Fire prevention symmetrical sleeve, d 110, d1 300 (price on request) [Code number: pm_110_300]
Details
|
pm_110_300 |
|
Application purpose:
- For pipeline communications made of combustible plastic materials (PP, PE, PVC)
- For residential (including multi-apartment) buildings, hotels and hostels, social and medical institutions, shopping centers, airports and railway stations, industrial enterprises, etc
- To protect premises from fire and smoke
Characteristics:
- It is an elongated fire sleeve equipped with two liners made of thermally expandable material (one on each side);
- Provides double fire protection - just one sleeve is enough for the length of the entire ceiling;
- The body is detachable, there is a tie-lock, so that the symmetrical fire coupling can be used on already installed pipelines;
- Metal parts are powder coated for corrosion protection;
- The clutch begins to work already at the 15th second when the temperature rises to +150 ° C, the complete overlap of the assembly occurs at the fourth minute;
- Swelling ratio: not less than 900%;
- Product color: grey;
- Fire resistance limit: 180 minutes;
- Service life: 30 years.
Operating principle:
During a fire, the thermally expanding liner of the fire muff expands tenfold, resulting in the formation of a solid foam-coke foam that fills the hole in the ceiling. This is quite effective at blocking fire.
Size |
Outside diameter |
Through Hole Diameter (minimum) |
Inner diameter |
Length |
Insert thickness |
|
mm |
mm |
mm |
mm |
mm |
PM-110 |
125 |
128 |
110 |
300 |
7 |
|
|
OGNEZA Fire collar with elongated mounts, d 110 (price on request) [Code number: pm_110_dlinnie_ushi]
Details
|
pm_110_dlinnie_ushi |
|
Application purposes:
- For preventing the spread of fire and combustion products through ceilings and walls
Characteristics:
- Housing consists of two parts, detachable
- High fire resistance - EI-180
- Products are certified
- Metal parts are painted with powder paint which increases the corrosion resistance
- Easy assembly/disassembly
- Coefficient of expansion is not less than 900%
- Collar is triggered at 15 seconds at temperature of +150 °C, complete overlap occurs at the intersection at 4 minute
- Keeps characteristics at temperatures from -50 °C to +80 °C
- 30 years lifetime
- Length of mounting lugs is 70 mm
Outside diameter |
Inner diameter |
Height |
Thickness of thermally expanding liner |
Colour |
Weight |
mm |
mm |
mm |
mm |
|
gr |
130,0 ± 3,0 |
110,0 ± 3,0 |
50,0/ 60,0 |
7,0 ± 1,0 |
light gray |
300 ± 20/ 315± 20 |
Download installation instruction: OGNEZA Fire collar
|
|
OGNEZA Fire collar, lock type "Light", gray, d 110 [Code number: pm_110_light]
Details
|
pm_110_light |
420 rub |
Application purposes:
- For preventing the spread of fire and combustion products through ceilings and walls
Characteristics:
- Housing consists of two parts, detachable
- High fire resistance - EI-180
- Products are certified
- Metal parts are painted with powder paint which increases the corrosion resistance
- Easy assembly/disassembly
- Coefficient of expansion is not less than 900%
- Collar is triggered at 15 seconds at temperature of +150 °C, complete overlap occurs at the intersection at 4 minute
- Keeps characteristics at temperatures from -50 °C to +80 °C
- 30 years lifetime
- Lock type: Light
Installation method
PM structure
- The case is a metal cuff and is made of cold-rolled or galvanized steel (thickness from 0.5 to 2 mm). Painted with weatherproof paint.
- The case is connected using a reliable Russian-made latch made of galvanized steel.
- The fire-retardant liner is located inside the coupling, held by the cloves bent inward. They also provide directional expansion of the fire retardant liner during a fire.
- The eyelets with holes can be easily bent. Their length is 35 mm, which simplifies installation.
Color: gray
Size |
Inner diameter |
Height |
Outside diameter |
Insert thickness |
Weight |
|
mm |
mm |
mm |
mm |
kg |
PM-110 |
110 |
50 |
130 |
7 |
0,300 |
Download installation instruction: OGNEZA Fire collar
|
|
OGNEZA Fire collar, lock type "Light", red, d 110 [Code number: pm_110_light_krasnie]
Details
|
pm_110_light_krasnie |
420 rub |
Application purposes:
- For preventing the spread of fire and combustion products through ceilings and walls
Characteristics:
- Housing consists of two parts, detachable
- High fire resistance - EI-180
- Products are certified
- Metal parts are painted with powder paint which increases the corrosion resistance
- Easy assembly/disassembly
- Coefficient of expansion is not less than 900%
- Collar is triggered at 15 seconds at temperature of +150 °C, complete overlap occurs at the intersection at 4 minute
- Keeps characteristics at temperatures from -50 °C to +80 °C
- 30 years lifetime
- Lock type: Light
Installation method
PM structure
- The case is a metal cuff and is made of cold-rolled or galvanized steel (thickness from 0.5 to 2 mm). Painted with weatherproof paint.
- The case is connected using a reliable Russian-made latch made of galvanized steel.
- The fire-retardant liner is located inside the coupling, held by the cloves bent inward. They also provide directional expansion of the fire retardant liner during a fire.
- The eyelets with holes can be easily bent. Their length is 35 mm, which simplifies installation.
Color: red
Size |
Inner diameter |
Height |
Outside diameter |
Insert thickness |
Weight |
|
mm |
mm |
mm |
mm |
kg |
PM-110 |
110 |
50 |
130 |
7 |
0,300 |
Download installation instruction: OGNEZA Fire collar
|
|
OGNEZA Fire collar, lock type "Light", gray, d 125 [Code number: pm_125]
Details
|
pm_125 |
1 048 rub |
Application purposes:
- For preventing the spread of fire and combustion products through ceilings and walls
Characteristics:
- Housing consists of two parts, detachable
- High fire resistance - EI-180
- Products are certified
- Metal parts are painted with powder paint which increases the corrosion resistance
- Easy assembly/disassembly
- Coefficient of expansion is not less than 900%
- Collar is triggered at 15 seconds at temperature of +150 °C, complete overlap occurs at the intersection at 4 minute
- Keeps characteristics at temperatures from -50 °C to +80 °C
- 30 years lifetime
- Lock type: Light
Installation method
PM structure
- The case is a metal cuff and is made of cold-rolled or galvanized steel (thickness from 0.5 to 2 mm). Painted with weatherproof paint.
- The case is connected using a reliable Russian-made latch made of galvanized steel.
- The fire-retardant liner is located inside the coupling, held by the cloves bent inward. They also provide directional expansion of the fire retardant liner during a fire.
- The eyelets with holes can be easily bent. Their length is 35 mm, which simplifies installation.
Outside diameter |
Inner diameter |
Height |
Thickness of thermally expanding liner |
Colour |
Weight |
mm |
mm |
mm |
mm |
|
gr |
145 |
125 |
50 |
7 |
gray |
355 |
Download installation instruction: OGNEZA Fire collar
|