Logo
Ru| En
Loading

Hauraton drainage channels for civil engineering

Concrete channels are reinforced with fiber and are intended for the use in industrial facilities. The drainage channels for civil engineering comply with the highest European standards of quality, and they are are certified to EN1433. Load class up to F900.

The channels are produced with special boltless locking system SIDE-LOCK which has high protection against corrosion. SIDE-LOCK system connects channel with grating in just 30 seconds.

The channels can have an angle housing ,ade of galvanized steel or cast iron. Length of the channels ranges from 500 to 4000 mm. Drainage cross-section can vary from 80 to 947 cm2.

Additional the Hauraton company produces channels with built-in fall 0.5% or 0.6%.

The channels are characterized by high resistance to adverse weather conditions.

Photo Name Article Price
Hauraton FASERFIX KS 100 Channel up to load class F 900, type 80, stainless steel, 1000x160x80 mm (price on request) [Code number: 1706]
Details
1706

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing: Stainless steel 1.4301

Application areas:

  • Railway platform
  • Facade drainage
  • Pedestrian zones
  • Gardening and landscaping
  • Multi storey car parks
  • Industrial buildings
  • Cable ducts
  • Sewage plants
  • Market squares, markets
  • Exhibition grounds, trade fairs
  • Public areas and squares
  • Car parking facilities
  • Cityscapes with architectural value
  • Car-Wash facilities
  • School yards
  • Road verge drainage
  • Underground car parks, multi-storey car parks
  • Access drives private

Product description:

FASERFIX KS 100 flat Type 80 - Channel made of fibre reinforced concrete, suitable for use in parking areas according to EN 1433, CE-conform, with stainless steel angle housing and boltless quick-locking system SIDELOCK, eigthfold locking, without crossing bars in the channel line, with safety joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 160 80 16,01 34

Download product data sheet: 1706 Hauraton FASERFIX KS 100 Channel up to load class F 900, type 80

Download the declaration of conformity: 1706 No.100

Download installation example: 1706 Concrete class A 15 - C 250

Download installation example: 1706 Pavement class A 15 - C 250

Download installation example: 1706 Concrete class A 15 - C 250

Download installation example: 1706 Concrete screed class A 15 - C 250

Download installation example: 1706 Concrete class A 15 - C 250

Download installation example: 1706 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 1706 Concrete class A 15 - D 400 with kerb

Download installation example: 1706 Pavement class A 15 - C 250

Download installation example: 1706 Asphalt class A 15 - E 600

Download installation example: 1706 Pavement class D 400 - E 600 with in-situ concrete stretcher

Download installation example: 1706 Concrete class D 400 - F 900

Download installation example: 1706 Pavement class D 400 - E 600

Download installation example: 1706 Concrete class D 400 - E 600

Download installation example: 1706 Asphalt class F 900

Hauraton FASERFIX KS 100 Channel up to load class F 900, type 100F, stainless steel, 1000x160x100 mm (price on request) [Code number: 1708]
Details
1708

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing: Stainless steel 1.4301

Application areas:

  • Railway platform
  • Facade drainage
  • Pedestrian zones
  • Gardening and landscaping
  • Multi storey car parks
  • Industrial buildings
  • Cable ducts
  • Sewage plants
  • Market squares, markets
  • Exhibition grounds, trade fairs
  • Public areas and squares
  • Car parking facilities
  • Cityscapes with architectural value
  • Car-Wash facilities
  • School yards
  • Road verge drainage
  • Underground car parks, multi-storey car parks
  • Access drives private

Product description:

FASERFIX KS 100 flat Type 100 - Channel made of fibre reinforced concrete, suitable for use in parking areas EN 1433, CE-conform, with stainless steel angle housing CNS 1.4301 and boltless quick-locking system SIDELOCK, eigthfold locking, without crossing bars in the channel line, with safety joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 160 100 19,23 54

Download product data sheet: 1708 Hauraton FASERFIX KS 100 Channel up to load class F 900, type 100

Download the declaration of conformity: 1708 No.100

Download installation example: 1708 Concrete class A 15 - C 250

Download installation example: 1708 Pavement class A 15 - C 250

Download installation example: 1708 Concrete class A 15 - C 250

Download installation example: 1708 Concrete screed class A 15 - C 250

Download installation example: 1708 Concrete class A 15 - C 250

Download installation example: 1708 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 1708 Concrete class A 15 - D 400 with kerb

Download installation example: 1708 Pavement class A 15 - C 250

Download installation example: 1708 Asphalt class A 15 - E 600

Download installation example: 1708 Pavement class D 400 - E 600 with in-situ concrete stretcher

Download installation example: 1708 Concrete class D 400 - F 900

Download installation example: 1708 Pavement class D 400 - E 600

Download installation example: 1708 Concrete class D 400 - E 600

Download installation example: 1708 Asphalt class F 900

Hauraton FASERFIX BIG SL 100 Channel up to class F 900, type 020, 1000x392x384 mm (price on request) [Code number: 1844]
Details
1844
Hauraton FASERFIX SUPER 150 Channel up to load class F 900, with galvanised angle housings, type 01, 1000x240x255 mm (price on request) [Code number: 2000]
Details
2000

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing: strip galvanized steel

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 01 - Channel made of fibre reinforced concrete, loading capacity from A 15 up to F 900 according to DIN19580 / EN 1433, CE-conform, with galvanised steel angle housing and boltless quicklocking system SIDE-LOCK.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 255 75,30 205

Download product data sheet: 2000 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 01

Download the declaration of conformity: 2000 No.105

Download installation example: 2000 Concrete class A 15 - C 250

Download installation example: 2000 Asphalt class D 400 - E 600

Download installation example: 2000 Concrete class D 400 - F 900 in ramps

Download installation example: 2000 Concrete class D 400 - F 900

Download installation example: 2000 Pavement class D 400 - E 600

Download installation example: 2000 Paving class D 400 - E 600 in ramps

Download installation example: 2000 Pavement class D 400 - E 600

Download installation example: 2000 Pavement class D 400 - E 600

Download installation example: 2000 Asphalt class A 15 - E 600 in ramps

Download installation example: 2000 Pavement class A 15 - C 250

Download installation example: 2000 Asphalt class A 15 - E 600

Download installation example: 2000 Concrete class A 15 - D 400 with kerb

Download installation example: 2000 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2000 Pavement class A 15 - C 250

Download installation example: 2000 Concrete class A 15 - C 250

Download installation example: 2000 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2000 Paving class A 15 - C 250 in ramps

Download installation example: 2000 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 1, 1000x240x255 - 261 mm (price on request) [Code number: 2001]
Details
2001

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1-19 - channel made of fibre reinforced concrete, loading capacity from A 15 - F 900 acc. EN 1433, CE-conform, with built-in fall 0.6 %, with galvanised steel angle housing and boltless quick-locking system SIDE-LOCK, eightfold locking, without crossing bars in the channel line.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 255 - 260 76,21 212

Download product data sheet: 2001 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 1

Download the declaration of conformity: 2001 No.105

Download installation example: 2001 Concrete class A 15 - C 250

Download installation example: 2001 Asphalt class D 400 - E 600

Download installation example: 2001 Concrete class D 400 - F 900 in ramps

Download installation example: 2001 Concrete class D 400 - F 900

Download installation example: 2001 Pavement class D 400 - E 600

Download installation example: 2001 Paving class D 400 - E 600 in ramps

Download installation example: 2001 Pavement class D 400 - E 600

Download installation example: 2001 Pavement class D 400 - E 600

Download installation example: 2001 Asphalt class A 15 - E 600 in ramps

Download installation example: 2001 Pavement class A 15 - C 250

Download installation example: 2001 Asphalt class A 15 - E 600

Download installation example: 2001 Concrete class A 15 - D 400 with kerb

Download installation example: 2001 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2001 Pavement class A 15 - C 250

Download installation example: 2001 Concrete class A 15 - C 250

Download installation example: 2001 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2001 Paving class A 15 - C 250 in ramps

Download installation example: 2001 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 2, 1000x240x261 - 267 mm (price on request) [Code number: 2002]
Details
2002

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1-19 - channel made of fibre reinforced concrete, loading capacity from A 15 - F 900 acc. EN 1433, CE-conform, with built-in fall 0.5 % with galvanised steel angle housing and boltless quick-locking system SIDE-LOCK, eightfold locking, without crossing bars in the channel line, with safety-joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 260 - 265 77,12 220

Download product data sheet: 2002 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 2

Download the declaration of conformity: 2002 No.105

Download installation example: 2002 Concrete class A 15 - C 250

Download installation example: 2002 Asphalt class D 400 - E 600

Download installation example: 2002 Concrete class D 400 - F 900 in ramps

Download installation example: 2002 Concrete class D 400 - F 900

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Paving class D 400 - E 600 in ramps

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Asphalt class A 15 - E 600 in ramps

Download installation example: 2002 Pavement class A 15 - C 250

Download installation example: 2002 Asphalt class A 15 - E 600

Download installation example: 2002 Concrete class A 15 - D 400 with kerb

Download installation example: 2002 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2002 Pavement class A 15 - C 250

Download installation example: 2002 Concrete class A 15 - C 250

Download installation example: 2002 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2002 Paving class A 15 - C 250 in ramps

Download installation example: 2002 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 3, 1000x240x267 - 273 mm (price on request) [Code number: 2003]
Details
2003

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1-19 - channel made of fibre reinforced concrete, loading capacity from A 15 - F 900 acc. EN 1433, CE-conform, with built-in fall 0.5 % and galvanised steel angle housing, with boltless quick-locking system SIDE-LOCK, eightfold locking, without crossing bars in the channel line.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 265 - 270 78,03 227

Download product data sheet: 2003 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 3

Download the declaration of conformity: 2003 No.105

Download installation example: 2003 Concrete class A 15 - C 250

Download installation example: 2003 Asphalt class D 400 - E 600

Download installation example: 2003 Concrete class D 400 - F 900 in ramps

Download installation example: 2003 Concrete class D 400 - F 900

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Paving class D 400 - E 600 in ramps

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Asphalt class A 15 - E 600 in ramps

Download installation example: 2003 Pavement class A 15 - C 250

Download installation example: 2003 Asphalt class A 15 - E 600

Download installation example: 2003 Concrete class A 15 - D 400 with kerb

Download installation example: 2003 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2003 Pavement class A 15 - C 250

Download installation example: 2003 Concrete class A 15 - C 250

Download installation example: 2003 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2003 Paving class A 15 - C 250 in ramps

Download installation example: 2003 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 4, 1000x240x273 - 279 mm (price on request) [Code number: 2004]
Details
2004

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.6 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 270 - 275 78,94 235

Download product data sheet: 2004 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 4

Download the declaration of conformity: 2004 No.105

Download installation example: 2004 Concrete class A 15 - C 250

Download installation example: 2004 Asphalt class D 400 - E 600

Download installation example: 2004 Concrete class D 400 - F 900 in ramps

Download installation example: 2004 Concrete class D 400 - F 900

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Paving class D 400 - E 600 in ramps

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Asphalt class A 15 - E 600 in ramps

Download installation example: 2004 Pavement class A 15 - C 250

Download installation example: 2004 Asphalt class A 15 - E 600

Download installation example: 2004 Concrete class A 15 - D 400 with kerb

Download installation example: 2004 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2004 Pavement class A 15 - C 250

Download installation example: 2004 Concrete class A 15 - C 250

Download installation example: 2004 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2004 Paving class A 15 - C 250 in ramps

Download installation example: 2004 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 5, 1000x240x279 - 285 mm (price on request) [Code number: 2005]
Details
2005

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 275 - 280 79,85 242

Download product data sheet: 2005 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 5

Download the declaration of conformity: 2005 No.105

Download installation example: 2005 Concrete class A 15 - C 250

Download installation example: 2005 Asphalt class D 400 - E 600

Download installation example: 2005 Concrete class D 400 - F 900 in ramps

Download installation example: 2005 Concrete class D 400 - F 900

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Paving class D 400 - E 600 in ramps

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Asphalt class A 15 - E 600 in ramps

Download installation example: 2005 Pavement class A 15 - C 250

Download installation example: 2005 Asphalt class A 15 - E 600

Download installation example: 2005 Concrete class A 15 - D 400 with kerb

Download installation example: 2005 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2005 Pavement class A 15 - C 250

Download installation example: 2005 Concrete class A 15 - C 250

Download installation example: 2005 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2005 Paving class A 15 - C 250 in ramps

Download installation example: 2005 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 6, 1000x240x285 - 291 mm (price on request) [Code number: 2006]
Details
2006

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE ­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 280 - 285 80,76 249

Download product data sheet: 2006 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 6

Download the declaration of conformity: 2006 No.105

Download installation example: 2006 Concrete class A 15 - C 250

Download installation example: 2006 Asphalt class D 400 - E 600

Download installation example: 2006 Concrete class D 400 - F 900 in ramps

Download installation example: 2006 Concrete class D 400 - F 900

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Paving class D 400 - E 600 in ramps

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Asphalt class A 15 - E 600 in ramps

Download installation example: 2006 Pavement class A 15 - C 250

Download installation example: 2006 Asphalt class A 15 - E 600

Download installation example: 2006 Concrete class A 15 - D 400 with kerb

Download installation example: 2006 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2006 Pavement class A 15 - C 250

Download installation example: 2006 Concrete class A 15 - C 250

Download installation example: 2006 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2006 Paving class A 15 - C 250 in ramps

Download installation example: 2006 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 7, 1000x240x291 - 297 mm (price on request) [Code number: 2007]
Details
2007

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE ­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 285 - 290 81,67 257

Download product data sheet: 2007 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 7

Download the declaration of conformity: 2007 No.105

Download installation example: 2007 Concrete class A 15 - C 250

Download installation example: 2007 Asphalt class D 400 - E 600

Download installation example: 2007 Concrete class D 400 - F 900 in ramps

Download installation example: 2007 Concrete class D 400 - F 900

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Paving class D 400 - E 600 in ramps

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Asphalt class A 15 - E 600 in ramps

Download installation example: 2007 Pavement class A 15 - C 250

Download installation example: 2007 Asphalt class A 15 - E 600

Download installation example: 2007 Concrete class A 15 - D 400 with kerb

Download installation example: 2007 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2007 Pavement class A 15 - C 250

Download installation example: 2007 Concrete class A 15 - C 250

Download installation example: 2007 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2007 Paving class A 15 - C 250 in ramps

Download installation example: 2007 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 8, 1000x240x297 - 303 mm (price on request) [Code number: 2008]
Details
2008

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­ conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 290 - 295 82,58 264

Download product data sheet: 2008 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 8

Download the declaration of conformity: 2008 No.105

Download installation example: 2008 Concrete class A 15 - C 250

Download installation example: 2008 Asphalt class D 400 - E 600

Download installation example: 2008 Concrete class D 400 - F 900 in ramps

Download installation example: 2008 Concrete class D 400 - F 900

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Paving class D 400 - E 600 in ramps

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Asphalt class A 15 - E 600 in ramps

Download installation example: 2008 Pavement class A 15 - C 250

Download installation example: 2008 Asphalt class A 15 - E 600

Download installation example: 2008 Concrete class A 15 - D 400 with kerb

Download installation example: 2008 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2008 Pavement class A 15 - C 250

Download installation example: 2008 Concrete class A 15 - C 250

Download installation example: 2008 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2008 Paving class A 15 - C 250 in ramps

Download installation example: 2008 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 9, 1000x240x303 - 309 mm (price on request) [Code number: 2009]
Details
2009

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 295 - 300 83,49 272

Download product data sheet: 2009 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 9

Download the declaration of conformity: 2009 No.105

Download installation example: 2009 Concrete class A 15 - C 250

Download installation example: 2009 Asphalt class D 400 - E 600

Download installation example: 2009 Concrete class D 400 - F 900 in ramps

Download installation example: 2009 Concrete class D 400 - F 900

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Paving class D 400 - E 600 in ramps

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Asphalt class A 15 - E 600 in ramps

Download installation example: 2009 Pavement class A 15 - C 250

Download installation example: 2009 Asphalt class A 15 - E 600

Download installation example: 2009 Concrete class A 15 - D 400 with kerb

Download installation example: 2009 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2009 Pavement class A 15 - C 250

Download installation example: 2009 Concrete class A 15 - C 250

Download installation example: 2009 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2009 Paving class A 15 - C 250 in ramps

Download installation example: 2009 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.5 %, up to load class F 900, type 10, 1000x240x309 - 315 mm (price on request) [Code number: 2010]
Details
2010

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 300 - 305 85,52 279

Download product data sheet: 2010 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 10

Download the declaration of conformity: 2010 No.105

Download installation example: 2010 Concrete class A 15 - C 250

Download installation example: 2010 Asphalt class D 400 - E 600

Download installation example: 2010 Concrete class D 400 - F 900 in ramps

Download installation example: 2010 Concrete class D 400 - F 900

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Paving class D 400 - E 600 in ramps

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Asphalt class A 15 - E 600 in ramps

Download installation example: 2010 Pavement class A 15 - C 250

Download installation example: 2010 Asphalt class A 15 - E 600

Download installation example: 2010 Concrete class A 15 - D 400 with kerb

Download installation example: 2010 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2010 Pavement class A 15 - C 250

Download installation example: 2010 Concrete class A 15 - C 250

Download installation example: 2010 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2010 Paving class A 15 - C 250 in ramps

Download installation example: 2010 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 11, 1000x240x315 - 321 mm (price on request) [Code number: 2011]
Details
2011

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. DIN 19580 / EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 305 - 310 86,65 285

Download product data sheet: 2011 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 11

Download the declaration of conformity: 2011 No.105

Download installation example: 2011 Concrete class A 15 - C 250

Download installation example: 2011 Asphalt class D 400 - E 600

Download installation example: 2011 Concrete class D 400 - F 900 in ramps

Download installation example: 2011 Concrete class D 400 - F 900

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Paving class D 400 - E 600 in ramps

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Asphalt class A 15 - E 600 in ramps

Download installation example: 2011 Pavement class A 15 - C 250

Download installation example: 2011 Asphalt class A 15 - E 600

Download installation example: 2011 Concrete class A 15 - D 400 with kerb

Download installation example: 2011 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2011 Pavement class A 15 - C 250

Download installation example: 2011 Concrete class A 15 - C 250

Download installation example: 2011 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2011 Paving class A 15 - C 250 in ramps

Download installation example: 2011 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 12, 1000x240x321 - 327 mm (price on request) [Code number: 2012]
Details
2012

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 310 - 315 87,76 293

Download product data sheet: 2012 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 12

Download the declaration of conformity: 2012 No.105

Download installation example: 2012 Concrete class A 15 - C 250

Download installation example: 2012 Asphalt class D 400 - E 600

Download installation example: 2012 Concrete class D 400 - F 900 in ramps

Download installation example: 2012 Concrete class D 400 - F 900

Download installation example: 2012 Pavement class D 400 - E 600

Download installation example: 2012 Paving class D 400 - E 600 in ramps

Download installation example: 2012 Pavement class D 400 - E 600

Download installation example: 2012 Pavement class D 400 - E 600

Download installation example: 2012 Asphalt class A 15 - E 600 in ramps

Download installation example: 2012 Pavement class A 15 - C 250

Download installation example: 2012 Asphalt class A 15 - E 600

Download installation example: 2012 Concrete class A 15 - D 400 with kerb

Download installation example: 2012 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2012 Pavement class A 15 - C 250

Download installation example: 2012 Concrete class A 15 - C 250

Download installation example: 2012 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2012 Paving class A 15 - C 250 in ramps

Download installation example: 2012 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 13, 1000x240x327 - 333 mm (price on request) [Code number: 2013]
Details
2013

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 315 - 320 88,88 300

Download product data sheet: 2013 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 13

Download the declaration of conformity: 2013 No.105

Download installation example: 2013 Concrete class A 15 - C 250

Download installation example: 2013 Asphalt class D 400 - E 600

Download installation example: 2013 Concrete class D 400 - F 900 in ramps

Download installation example: 2013 Concrete class D 400 - F 900

Download installation example: 2013 Pavement class D 400 - E 600

Download installation example: 2013 Paving class D 400 - E 600 in ramps

Download installation example: 2013 Pavement class D 400 - E 600

Download installation example: 2013 Pavement class D 400 - E 600

Download installation example: 2013 Asphalt class A 15 - E 600 in ramps

Download installation example: 2013 Pavement class A 15 - C 250

Download installation example: 2013 Asphalt class A 15 - E 600

Download installation example: 2013 Concrete class A 15 - D 400 with kerb

Download installation example: 2013 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2013 Pavement class A 15 - C 250

Download installation example: 2013 Concrete class A 15 - C 250

Download installation example: 2013 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2013 Paving class A 15 - C 250 in ramps

Download installation example: 2013 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 14, 1000x240x333 - 339 mm (price on request) [Code number: 2014]
Details
2014

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 320 - 325 90,00 307

Download product data sheet: 2014 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 14

Download the declaration of conformity: 2014 No.105

Download installation example: 2014 Concrete class A 15 - C 250

Download installation example: 2014 Asphalt class D 400 - E 600

Download installation example: 2014 Concrete class D 400 - F 900 in ramps

Download installation example: 2014 Concrete class D 400 - F 900

Download installation example: 2014 Pavement class D 400 - E 600

Download installation example: 2014 Paving class D 400 - E 600 in ramps

Download installation example: 2014 Pavement class D 400 - E 600

Download installation example: 2014 Pavement class D 400 - E 600

Download installation example: 2014 Asphalt class A 15 - E 600 in ramps

Download installation example: 2014 Pavement class A 15 - C 250

Download installation example: 2014 Asphalt class A 15 - E 600

Download installation example: 2014 Concrete class A 15 - D 400 with kerb

Download installation example: 2014 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2014 Pavement class A 15 - C 250

Download installation example: 2014 Concrete class A 15 - C 250

Download installation example: 2014 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2014 Paving class A 15 - C 250 in ramps

Download installation example: 2014 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 15, 1000x240x339 - 345 mm (price on request) [Code number: 2015]
Details
2015

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 325 - 330 91,12 315

Download product data sheet: 2015 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 15

Download the declaration of conformity: 2015 No.105

Download installation example: 2015 Concrete class A 15 - C 250

Download installation example: 2015 Asphalt class D 400 - E 600

Download installation example: 2015 Concrete class D 400 - F 900 in ramps

Download installation example: 2015 Concrete class D 400 - F 900

Download installation example: 2015 Pavement class D 400 - E 600

Download installation example: 2015 Paving class D 400 - E 600 in ramps

Download installation example: 2015 Pavement class D 400 - E 600

Download installation example: 2015 Pavement class D 400 - E 600

Download installation example: 2015 Asphalt class A 15 - E 600 in ramps

Download installation example: 2015 Pavement class A 15 - C 250

Download installation example: 2015 Asphalt class A 15 - E 600

Download installation example: 2015 Concrete class A 15 - D 400 with kerb

Download installation example: 2015 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2015 Pavement class A 15 - C 250

Download installation example: 2015 Concrete class A 15 - C 250

Download installation example: 2015 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2015 Paving class A 15 - C 250 in ramps

Download installation example: 2015 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 16, 1000x240x345 - 351 mm (price on request) [Code number: 2016]
Details
2016

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 type 1 ­ 19 ­ Channel made of fibre reinforced concrete, loading capacity from A 15 up to F 900 according to EN 1433, CE­ conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 330 - 335 92,24 322

Download product data sheet: 2016 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 16

Download the declaration of conformity: 2016 No.105

Download installation example: 2016 Concrete class A 15 - C 250

Download installation example: 2016 Asphalt class D 400 - E 600

Download installation example: 2016 Concrete class D 400 - F 900 in ramps

Download installation example: 2016 Concrete class D 400 - F 900

Download installation example: 2016 Pavement class D 400 - E 600

Download installation example: 2016 Paving class D 400 - E 600 in ramps

Download installation example: 2016 Pavement class D 400 - E 600

Download installation example: 2016 Pavement class D 400 - E 600

Download installation example: 2016 Asphalt class A 15 - E 600 in ramps

Download installation example: 2016 Pavement class A 15 - C 250

Download installation example: 2016 Asphalt class A 15 - E 600

Download installation example: 2016 Concrete class A 15 - D 400 with kerb

Download installation example: 2016 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2016 Pavement class A 15 - C 250

Download installation example: 2016 Concrete class A 15 - C 250

Download installation example: 2016 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2016 Paving class A 15 - C 250 in ramps

Download installation example: 2016 Asphalt class F 9000

See also