Logo
Ru| En
Loading

Wavin AS+ Couplings

Wavin AS+ couplings, like other fittings of the system, are painted in light gray, which makes it easy to fit the pipeline into the design of the room. They are made of polypropylene reinforced with mineral additives, due to which the Wavin AS+ pipeline system is distinguished by increased noise insulation.

Wavin AS + couplings are divided into several types:

  • repair couplings are designed to repair damaged pipeline sections;
  • double-socket couplings are made of high quality PP, due to which they have increased resistance to temperature changes, strength and stiffness.
Photo Наименование Article Цена
Wavin AS+ Double socket coupling, d 110 [Code number: 3080012]
Details
3080012 760 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
100 124 111 111 5 0,391
Wavin AS+ Double socket coupling, d 125 [Code number: 3080013]
Details
3080013 1 305 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
125 132 125 125 5 0,512
Wavin AS+ Double socket coupling, d 160 [Code number: 3080014]
Details
3080014 1 376 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
150 148 160 160 5 0,755
Wavin AS+ Double socket coupling, d 200 [Code number: 3080015]
Details
3080015 2 387 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
200 181 201 201 8 1,327
Wavin AS+ Double socket coupling, d 50 [Code number: 3080016]
Details
3080016 453 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
50 99 50 50 3 0,123
Wavin AS+ Double socket coupling, d 75 [Code number: 3080017]
Details
3080017 523 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
70 107 75 75 3 0,174
Wavin AS+ Double socket coupling, d 90 [Code number: 3080018]
Details
3080018 831 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Z1 Weight
mm mm mm mm mm kg
90 114 90 90 3 0,263
Wavin AS+ Repair coupling, d 110 [Code number: 3080088]
Details
3080088 738 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
100 124 110 110 0,387
Wavin AS+ Repair coupling, d 125 [Code number: 3080089]
Details
3080089 1 290 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
125 132 125 125 0,512
Wavin AS+ Repair coupling, d 160 [Code number: 3080090]
Details
3080090 1 869 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
150 148 160 160 0,755
Wavin AS+ Repair coupling, d 200 [Code number: 3080091]
Details
3080091 2 109 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
200 181 201 201  
Wavin AS+ Repair coupling, d 50 [Code number: 3080092]
Details
3080092 468 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
50 99 50 50 0,121
Wavin AS+ Repair coupling, d 75 [Code number: 3080093]
Details
3080093 535 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
70 107 75 75 0,170
Wavin AS+ Repair coupling, d 90 [Code number: 3080094]
Details
3080094 823 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter L Ds1 Ds2 Weight
mm mm mm mm kg
90 114 90 90 0,263

See also