Logo
Ru| En
Loading

Wavin AS+ Cross pipes

Photo Наименование Article Цена
Wavin AS+ Corner branch 87°, d 110, d1 110, d2 110 [Code number: 3080008]
Details
3080008 1 812 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter a Do1 L Ds2 Ds3 Ds4 Z1 Z2 Z3 Z4 Weight
mm   mm mm mm mm mm mm mm mm mm kg
100/100/100 87° 110 251 110 110 110 122 139 128 139 1,131
Wavin AS+ Corner branch 87°, d 90, d1 90, d2 90 [Code number: 3080009]
Details
3080009 9 130 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter a Do1 L Ds2 Ds3 Ds4 Z1 Z2 Z3 Z4 Weight
mm   mm mm mm mm mm mm mm mm mm kg
90/90/90 87° 90 218 90 90 90 111 66 51 51 0,856
Wavin AS+ Double branch 87°, IR inner radius, d 90, d1 90, d2 90 [Code number: 3080010]
Details
3080010 1 785 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z1 Z2 Z3 Z4 Weight
mm mm mm mm mm mm mm mm mm mm kg
100/100/100 11 255 110 110 110 139 81 60 81 1,263
Wavin AS+ Double branch 87°, IR inner radius, d 110, d1 110, d2 110 [Code number: 3080011]
Details
3080011 1 533 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z1 Z2 Z3 Z4 Weight
mm mm mm mm mm mm mm mm mm mm kg
90/90/90 90 224 90 90 90 124 68 48 68 0,820
Wavin AS+ Parallel T-piece 87°, d 110, d1 110, d2 50 [Code number: 3080095]
Details
3080095 9 090 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
100/100/50 110 330 50 110 110 126 87 59 81 1,78
Wavin AS+ Parallel corner T-piece T-piece 87°, left, d 110, d1 110, d2 50 [Code number: 3080096]
Details
3080096 9 108 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • left
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
100/100/50 110 330 50 110 110 126 87 59 81 1,78
Wavin AS+ Parallel corner T-piece T-piece 87°, right, d 110, d1 110, d2 50 [Code number: 3080097]
Details
3080097 9 108 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • right
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
100/100/50 110 330 50 110 110 126 87 59 81 1,78
Wavin AS+ Parallel T-piece 87°, d 90, d1 90, d2 50 [Code number: 3080098]
Details
3080098 9 288 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
90/90/50 90 296 50 90 90 114 82 51 68 1,11
Wavin AS+ Parallel corner T-piece T-piece 87°, left, d 90, d1 90, d2 50 [Code number: 3080099]
Details
3080099 9 166 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • left
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
90/90/50 90 296 50 90 90 114 82 51 68 1,11
Wavin AS+ Parallel corner T-piece T-piece 87°, right, d 90, d1 90, d2 50 [Code number: 3080100]
Details
3080100 9 288 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • right
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
90/90/50 90 296 50 90 90 114 82 51 68 1,11
Wavin AS+ Combined double branch, d 110, d1 110, d2 75 [Code number: 3080109]
Details
3080109 11 868 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Size: 100/100/70 mm
Wavin AS+ Parallel T-piece 87°, d 110, d1 110, d2 75 [Code number: 3080110]
Details
3080110 9 148 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
100/100/70 110 330 75 110 110 126 87 59 81 1,83
Wavin AS+ Parallel T-piece 87°, d 90, d1 90, d2 75 [Code number: 3080111]
Details
3080111 9 692 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Linear coefficient of thermal expansion: 0.06 mm / mK
Diameter Do1 L Ds2 Ds3 Ds4 Z Z1 Z2 Z3 Weight
mm mm mm mm mm mm mm mm mm mm kg
90/90/70 90 296 75 90 90 114 82 51 68 1,18