Logo
Ru| En
Loading

Wavin AS+ Pipes

Wavin AS + pipes are made of high-quality polypropylene reinforced with minerals, which provides high noise protection.

They are distinguished by their durability and resistance to various environments, including aggressive ones. The material from which the pipes are made is characterized by low weight, which makes the elements of the Wavin AS + system lightweight. The material is smooth, which makes the pipe surface resistant to deposits.

Wavin AS + pipes are used in free-flow sewage systems, they can have a diameter from 50 to 200 mm. They are able to withstand waste water temperatures up to +90 ° C and for a short period up to +95 ° C. The linear thermal expansion coefficient is 0.06 mm / mK. Fire safety class B2.

Photo Name Article Price
Wavin AS+ Pipe with socket, PP, d 110, length 0.15 m, price for 1 piece [Code number: 3080030]
Details
3080030 662 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 209 150 0,675

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 0.25 m, price for 1 piece [Code number: 3080031]
Details
3080031 905 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 309 250 1,017

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 0.5 m, price for 1 piece [Code number: 3080032]
Details
3080032 965 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 559 500 1,830

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 1 m, price for 1 piece [Code number: 3080033]
Details
3080033 1 670 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 1059 1000 3,407

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 2 m, price for 1 piece [Code number: 3080034]
Details
3080034 3 065 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 2059 2000 6,562

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 2,7 m, price for 1 piece [Code number: 3080035]
Details
3080035 3 983 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 2759 2700 8,770

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 110, length 3 m, price for 1 piece [Code number: 3080036]
Details
3080036 4 434 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
100 110/111 3059 3000 9,716

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
100 110 99,4 5,3 59
Wavin AS+ Pipe with socket, PP, d 125, length 0.15 m, price for 1 piece [Code number: 3080037]
Details
3080037 1 114 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/125 213 150 0,788

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 0.25 m, price for 1 piece [Code number: 3080038]
Details
3080038 1 307 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/125 313 250 1,155

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 0.5 m, price for 1 piece [Code number: 3080039]
Details
3080039 1 158 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/126 562 500 2,092

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 1 m, price for 1 piece [Code number: 3080040]
Details
3080040 2 012 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/126 1062 1000 3,895

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 2 m, price for 1 piece [Code number: 3080041]
Details
3080041 3 635 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/126 2062 2000 7,502

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 2,7 m, price for 1 piece [Code number: 3080042]
Details
3080042 4 693 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/126 2762 2700 10,026

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 125, length 3 m, price for 1 piece [Code number: 3080043]
Details
3080043 5 225 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
125 125/126 3062 3000 11,109

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
125 125 114,4 5,3 63
Wavin AS+ Pipe with socket, PP, d 160, length 0.15 m, price for 1 piece [Code number: 3080044]
Details
3080044 1 323 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/160 221,4 150 1,088

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71
Wavin AS+ Pipe with socket, PP, d 160, length 0.25 m, price for 1 piece [Code number: 3080045]
Details
3080045 1 544 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/160 321,4 250 1,088

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71
Wavin AS+ Pipe with socket, PP, d 160, length 0.5 m, price for 1 piece [Code number: 3080046]
Details
3080046 1 693 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/161 570,2 500 2,865

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71
Wavin AS+ Pipe with socket, PP, d 160, length 1 m, price for 1 piece [Code number: 3080047]
Details
3080047 2 811 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/161 1070 1000 5,334

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71
Wavin AS+ Pipe with socket, PP, d 160, length 2 m, price for 1 piece [Code number: 3080048]
Details
3080048 5 021 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/161 2070 2000 10,272

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71
Wavin AS+ Pipe with socket, PP, d 160, length 2,7 m, price for 1 piece [Code number: 3080049]
Details
3080049 6 562 rub

Application purpose:

  • For pipeline installation in buildings, on roofs and for underground installation
  • For buildings with increased requirements for sound insulation
  • For long-term exposure to drains with temperatures up to +90 °С

Characteristics:

  • Meets or exceeds DIN EN 12056 and DIN 1986-100
  • Chemical resistance in the pH range 2 - 12
  • Material: polypropylene reinforced with minerals
  • Density: 1.9 g / cm3
  • Elastic moduli: 1800 N / mm2
  • Fire resistance: DIN 4102, B2 and EN13501 D-S3, d0
  • Temperature range: Short-term +95 °C and +90 °C constant
  • Linear coefficient of thermal expansion: 0.06 mm / mK
  • Color: Light gray RAL 7035
Diameter Do1/Ds2 L Z1 Weight
mm mm mm mm kg
150 160/161 2770 2700 13,730

System parameters

Diameter Outside diameter, d Inner diameter, di Wall thickness, s Socket depth
mm mm mm mm mm
150 160 148,8 5,6 71

See also