Logo
Ru| En
Loading

Fastening system of Wavin Quick Stream

Fastening elements for Wavin Quick Stream system are used for installation of rainwater system. They include:

  • Pipe clamps;
  • Screw nuts and bolts;
  • Clips for hanger;
  • Rail connectors etc.
Photo Наименование Article Цена
Wavin QuickStream clip for hanger, M6 (on request) [Code number: 26506326]
Details
26506326

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream clip for hanger is suitable for installation of roof drainage systems. You can see the appearance of clip for hanger and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.

Technical characteristics

Material: steel

M A B C L H Mounting rail
  mm mm mm mm mm  
M6 37 60 80 43,8 18 30/30 – 30/45
Wavin QuickStream eye nut, M10x10,5 (on request) [Code number: 26511320]
Details
26511320

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream eye nut is suitable for installation of roof drainage systems. There is a thread M10.You can see the appearance of nut in the photo.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
Wavin QuickStream base plate, square, d 1/2" [Code number: 3033180 / 26502315]
Details
3033180 434 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream base plate is suitable for installation of roof drainage systems. The form is square. You can see the appearance of base plate and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.

Technical characteristics

Material: steel.

G A B t
  mm mm mm
1/2" 40 120 4,0
Wavin QuickStream base plate, square, d 1" [Code number: 3033207 / 26503315]
Details
3033207 642 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream base plate is suitable for installation of roof drainage systems. The form is square. You can see the appearance of base plate and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.

Technical characteristics

Material: steel.

G A B t
  mm mm mm
1" 40 120 4,3
Wavin QuickStream Connecting elbow UV 53/UV 69, d 63x2” (on request) [Code number: 3043470]
Details
3043470

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2" 63 210
Wavin QuickStream Connecting elbow UV 53/UV 69, d 40x2,5” [Code number: 3043471]
Details
3043471 3 538 rub

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2,5" 40 180
Wavin QuickStream Connecting elbow UV 53/UV 69, d 50x2,5” [Code number: 3043472]
Details
3043472 2 755 rub

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2,5" 50 180
Wavin QuickStream Connecting elbow UV 53/UV 69, d 56, G 2,5” [Code number: 3043473]
Details
3043473 2 886 rub

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2,5" 56 210
Wavin QuickStream Connecting elbow UV 53/UV 69, d 63x2,5” [Code number: 3043474]
Details
3043474 2 785 rub

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2,5" 63 210
Wavin QuickStream Connecting elbow UV 53/UV 69, d 75x2,5” [Code number: 3043475]
Details
3043475 2 537 rub

Application purposes:

  • To drain rainwater and melt water

Material: high density polyethylene

Application purposes:

  • Savings at the expense less roof outlets
  • Mounting without tilting horizontal collector
  • Low weight
  • No air enters through the funnels
G Ø A
  mm mm
2,5" 75 210
Wavin QuickStream pipe clamp assembly, d 40 [Code number: 4011966 / 26523311]
Details
4011966 740 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
40 75 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 50 [Code number: 4011971 / 26526311]
Details
4011971 790 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
50 85 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 63 [Code number: 4011972 / 26534311]
Details
4011972 777 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
63 98 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 75 [Code number: 4011973 / 26537311]
Details
4011973 790 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
75 110 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 90 [Code number: 4011974 / 26540311]
Details
4011974 803 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
90 125 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 110 [Code number: 4011975 / 26546311]
Details
4011975 844 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
110 145 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 125 [Code number: 4011976 / 26548311]
Details
4011976 876 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
125 160 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 160 [Code number: 4011977 / 26556311]
Details
4011977 966 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
160 195 30 x 3,0
Wavin QuickStream pipe clamp assembly, d 56 [Code number: 4011978 / 26528311]
Details
4011978 768 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp assembly is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings to horizontal and vertical surfaces. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.
DN a b x s
mm mm mm
56 91 30 x 3,0
Wavin QuickStream pipe clamp lighter, d 56 [Code number: 4023394 / 26528330]
Details
4023394 385 rub

Application purposes:

  • For installation of roof drainage systems

Description

Wavin QuickStream pipe clamp lighter is suitable for installation of roof drainage systems. The pipe clamp lighter is used for reliable fixation of pipes and fittings. You can see the appearance of pipe clamp lighter and its dimensions in the photo and draft.

Wavin QuickStream piping system has the following advantages:

  • Shock resistance;
  • Resistance to low and high temperatures;
  • Low weight of system elements;
  • High capacity of roof outlets etc.

Technical characteristics

Material: steel.

DN a b
mm mm mm
56 143 63

See also