Logo
Ru| En
Loading

Viking Johnson AquaFast flange adapters

Viking Johnson AquaFast flange adapters are made of malleable cast iron and equipped with an EPDM gasket.

Viking Johnson AquaFast flange adapters are used to connect pipes to the flanges of valves and other equipment. Also, the use of adapters will compensate for a slight stretching of the pipes.

Operating pressure 10/16 bar.

Key features of Viking Johnson AquaFast flange adapters:

  • suitable for PE and PVC pipes;
  • no additional support for PE pipes is required;
  • no torque wrench is required - the bolts are tightened to a stupor;
  • resistant to corrosion;
  • provide reliable and completely tight connection.
Photo Name Article Price
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 110 mm [Code number: AF110]
Details
AF110

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
110 100 PN10,16 2-M12 x 135 144 229,5 100 17 20 25 5,4
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 125 mm [Code number: AF125]
Details
AF125

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
125 100/125 PN10,16 2-M12 x 135 144 250 100 17 20 25 6,3
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 140 mm [Code number: AF140]
Details
AF140

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
140 125 PN10,16 4-M12 x 135 144 250 125 17 20 25 6,4
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 150 mm [Code number: AF150]
Details
AF150

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
160 150 PN10,16 4-M12 x 135 144 285,5 150 17 20 25 7,3
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 180 mm [Code number: AF180]
Details
AF180

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
180 150 PN10,16 4-M12 x 185 195 285,5 150 17 25 35 10,2
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 200 mm [Code number: AF200]
Details
AF200

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
200 200 PN10,16 4-M12 x 185 195 343 190 18 25 35 13
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 225 mm [Code number: AF225]
Details
AF225

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
225 200 PN10,16 4-M16 x 195 205 342,5 190 18 25 35 14,5
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 250 mm [Code number: AF250]
Details
AF250 48 120 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
250 250 PN10,16 6-M16 x 195 208 406 240 20 25 35 19,5
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 280 mm [Code number: AF280]
Details
AF280

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
280 250 PN10,16 6-M16 x 195 207 406 270 20 25 35 22.1
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 315 mm [Code number: AF315]
Details
AF315 63 860 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: aluminum alloy 6063 state T6
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
315 300 PN10,16 6-M16 x 195 209 483 300 21,5 25 35 24,6
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 355 mm [Code number: AF355]
Details
AF355 116 000 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Flange Adaptor Body, Centre Sleeve, Clamp Bands & Gripper Ring: Ductile iron to BS EN 1563 Symbol EN-GJS-450-10
  • Bolts: Stainless Steel BS EN ISO3506-1 Grade A2-70
  • Nuts: Stainless Steel BS EN ISO3506-2 Grade A4-80
  • Sealing collar: EPDM Grade ‘E’ to BS EN 681-1:1996 Type WA WRAS listed

Coatings:

  • Body, Sleeve, Intermediate Ring & End Ring: Rilsan Nylon 11 to WIS 4-52-01 Part 1
  • Nuts and Bolts: Sheraplex coated to WIS 4-52-03
Outer diameter of the pipe Flange drillings Bolts size
No.-Dia x Length
Insertion Depth Setting gap (based on nominal insertion depth) Clamp Band Outer Diameter (A) Length (L) Flange Outer Diameter (B) Flange Thickness (T) Weight
      Min Nom Max   Installed Uninstalled        
mm mm mm mm mm mm mm mm mm mm mm mm kg
355 350 PN10,16 12-M16 x 120 284 304 324 117 540 571 421 520 23.5 120.0
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 400 mm [Code number: AF400]
Details
AF400

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Flange Adaptor Body, Centre Sleeve, Clamp Bands & Gripper Ring: Ductile iron to BS EN 1563 Symbol EN-GJS-450-10
  • Bolts: Stainless Steel BS EN ISO3506-1 Grade A2-70
  • Nuts: Stainless Steel BS EN ISO3506-2 Grade A4-80
  • Sealing collar: EPDM Grade ‘E’ to BS EN 681-1:1996 Type WA WRAS listed

Coatings:

  • Body, Sleeve, Intermediate Ring & End Ring: Rilsan Nylon 11 to WIS 4-52-01 Part 1
  • Nuts and Bolts: Sheraplex coated to WIS 4-52-03
Outer diameter of the pipe Flange drillings Bolts size
No.-Dia x Length
Insertion Depth Setting gap (based on nominal insertion depth) Clamp Band Outer Diameter (A) Length (L) Flange Outer Diameter (B) Flange Thickness (T) Weight
      Min Nom Max   Installed Uninstalled        
mm mm mm mm mm mm mm mm mm mm mm mm kg
400 400 PN10,16 12-M16 x 120 290 310 330 117 585 618 427 580 25 132.0
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 450 mm [Code number: AF450]
Details
AF450 180 300 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Flange Adaptor Body, Centre Sleeve, Clamp Bands & Gripper Ring: Ductile iron to BS EN 1563 Symbol EN-GJS-450-10
  • Bolts: Stainless Steel BS EN ISO3506-1 Grade A2-70
  • Nuts: Stainless Steel BS EN ISO3506-2 Grade A4-80
  • Sealing collar: EPDM Grade ‘E’ to BS EN 681-1:1996 Type WA WRAS listed

Coatings:

  • Body, Sleeve, Intermediate Ring & End Ring: Rilsan Nylon 11 to WIS 4-52-01 Part 1
  • Nuts and Bolts: Sheraplex coated to WIS 4-52-03
Outer diameter of the pipe Flange drillings Bolts size
No.-Dia x Length
Insertion Depth Setting gap (based on nominal insertion depth) Clamp Band Outer Diameter (A) Length (L) Flange Outer Diameter (B) Flange Thickness (T) Weight
      Min Nom Max   Installed Uninstalled        
mm mm mm mm mm mm mm mm mm mm mm mm kg
450 450 PN10,16 12-M16 x 120 298 318 338 117 635 670 435 640 27 147.2
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 63 mm [Code number: AF63]
Details
AF63 10 600 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
63 50/65 PN10,16 2-M12 x 135 144 185 50 17 20 25 3,7
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 75 mm [Code number: AF75]
Details
AF75 4 400 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
75 60 PN10,16 2-M12 x 135 144 200 65 17 20 25 4,3
Viking Johnson AquaFast Adaptor for pipes made of PE and PVC, d 90 mm [Code number: AF90]
Details
AF90 6 400 rub

Application purpose:

  • For joining pipes made of PE and PVC to the flanges of valves, counters, tie-ins and other equipment
  • For neutral liquids at permissible operating temperature + 50 °С

Characteristics:

  • Operating pressure up to 16 bar
  • One type of flange for PE and PVC pipes
  • No additional support for PE pipes required
  • No torque wrench required - bolts tighten to stop
  • The gap between the ends of the pipes is necessary to: compensate for thermal expansion, prevent transmission of vibration, compensate for sedimentation and facilitate installation/dismantling

Installation:

  • The pipe is inserted into a freely assembled flange, with a gap between the end of the pipe and the flange plane of about 20 mm (chamfering is not required)
  • Pressure ring bolts tighten all the way

Materials:

  • Central adapter, pressure ring and housing: Ductile iron in accordance with BS EN 1563:1997
  • Locking ring: Zinc alloy in accordance with BS EN 12844:1999
  • Intermediate ring: Malleable cast iron in accordance with BS EN 1563:1997
  • Bolts: Steel BS EN ISO 898-1: 2009 Material Category 8.8
  • Nuts: Steel to BS EN20898-2: 1994 grade 8
  • Sealing collar: EPDM

Coatings:

  • Center adapter, pressure ring, and intermediate ring: Rilsan Nylon 11
  • Locking ring: cataphoretic coating
  • Bolts, nuts: Sheraplex conforming to WIS 4-52-03
Outer diameter of the pipe Flange drillings Tee bolt size
No.-Dia x Length
Dimensions Bore (C) Flange thickness (D) Landing gap Maximum gap Weight
      Installed Uninstalled          
mm mm mm mm mm mm mm mm mm kg
90 65/80 PN10,16 2-M12 x 135 144 200 80 17 20 25 4,4

See also