Logo
Ru| En
Loading

Ostendorf HT bends of polypropylene

Ostendorf HT bends have an inclination angle of 15°, 30°, 45°, 67° and 87°. They are painted in gray but there are special bends which are painted in white.

They bend is a bent pipe intended for mounting the pipeline in corners or for changing the direction of pipeline.

Ostendorf HT bends are characterized by durability, chemical resistance, corrosion resistance.

Photo Наименование Article Цена
Ostendorf HT Bend 30° HTBw, white, d 50 [Code number: 559410 (O)]
Details
559410 (O) 31 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: white

d α Z1 Z2 l1
mm mm mm mm mm
50 30° 9 13 46

Download the installation instructions of product: 559410 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTBw, white, d 50 [Code number: 559440]
Details
559440 28 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: white

d α Z1 Z2 l1
mm mm mm mm mm
50 87° - - -

Download the installation instructions of product: 559440 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 32 [Code number: 110100]
Details
110100 46 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
32 15° 3 8 42

Download the installation instructions of product: 110100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 40 [Code number: 111100]
Details
111100 36 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
40 15° 5 9 44

Download the installation instructions of product: 111100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 40 [Code number: 111110]
Details
111110 36 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
40 30° 7 11 44

Download the installation instructions of product: 111110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 40 [Code number: 111130]
Details
111130 38 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
40 67° 16 20 44

Download the installation instructions of product: 111130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 40 [Code number: 111140]
Details
111140 36 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
40 87° 23 26 42

Download the installation instructions of product: 111140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 50 [Code number: 112100]
Details
112100 28 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
50 15° 5 9 46

Download the installation instructions of product: 112100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 50 [Code number: 112110]
Details
112110 30 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
50 30° 9 13 46

Download the installation instructions of product: 112110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 50 [Code number: 112120]
Details
112120 25 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
50 45° 12 16 46

Download the installation instructions of product: 112120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 50 [Code number: 112130]
Details
112130 44 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
50 67° 22 23 46

Download the installation instructions of product: 112130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 75 [Code number: 113100]
Details
113100 55 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
75 15° 7 11 51

Download the installation instructions of product: 113100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 75 [Code number: 113110]
Details
113110 61 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
75 30° 12 16 51

Download the installation instructions of product: 113110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 75 [Code number: 113130]
Details
113130 65 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
75 67° 28 31 51

Download the installation instructions of product: 113130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 75 [Code number: 113140]
Details
113140 69 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
75 87° 40 43 51

Download the installation instructions of product: 113140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 90 [Code number: 114130]
Details
114130 112 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
90 67° 32 36 54

Download the installation instructions of product: 114130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 110 [Code number: 115100]
Details
115100 83 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
110 15° 9 17 58

Download the installation instructions of product: 115100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 110 [Code number: 115110]
Details
115110 91 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
110 30° 17 24 58

Download the installation instructions of product: 115110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 110 [Code number: 115120]
Details
115120 77 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
110 45° 17 24 58

Download the installation instructions of product: 115120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 110 [Code number: 115140]
Details
115140 90 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
110 87° 57 61 58

Download the installation instructions of product: 115140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 125 [Code number: 116100]
Details
116100 256 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
125 15° 10 17 64

Download the installation instructions of product: 116100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 125 [Code number: 116110]
Details
116110 256 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
125 30° 19 25 64

Download the installation instructions of product: 110100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 125 [Code number: 116130]
Details
116130 347 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
125 67° 40 44 58

Download the installation instructions of product: 116130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 125 [Code number: 116140]
Details
116140 456 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
125 87° 65 71 64

Download the installation instructions of product: 116140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTB, d 160 [Code number: 117100]
Details
117100 568 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
160 15° 13 22 73

Download the installation instructions of product: 117100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 160 [Code number: 117110]
Details
117110 586 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
160 30° 24 32 73

Download the installation instructions of product: 117110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 160 [Code number: 117140]
Details
117140 640 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
160 87° 83 96 73

Download the installation instructions of product: 117140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTBw, white, d 32 [Code number: 559310]
Details
559310 48 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: white

d α Z1 Z2 l1
mm mm mm mm mm
32 30° 6 10 42

Download the installation instructions of product: 559310 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTBw, white, d 32 [Code number: 559320]
Details
559320 48 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: white

d α Z1 Z2 l1
mm mm mm mm mm
32 45° 9 12 42

Download the installation instructions of product: 559320 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 67° HTB, d 32 [Code number: 110130]
Details
110130 53 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
32 67° 14 17 42

Download the installation instructions of product: 110130 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 50 [Code number: 112140]
Details
112140 27 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
50 87° 28 31 46

Download the installation instructions of product: 112140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 40 [Code number: 111120]
Details
111120 36 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
40 45° 10 14 44

Download the installation instructions of product: 111120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 15° HTBw, white, d 32 [Code number: 559300]
Details
559300 48 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: white

d α Z1 Z2 l1
mm mm mm mm mm
32 15° 3 8 42

Download the installation instructions of product: 110100 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 90 [Code number: 114120]
Details
114120 99 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
90 45° 20 25 54

Download the installation instructions of product: 114120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 32 [Code number: 110140]
Details
110140 46 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
32 87° 19 23 42

Download the installation instructions of product: 110140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 30° HTB, d 90 [Code number: 114110]
Details
114110 99 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
90 30° 13 18 54

Download the installation instructions of product: 114110 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 87° HTB, d 90 [Code number: 114140]
Details
114140 112 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
90 87° 46 49 54

Download the installation instructions of product: 114140 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 160 [Code number: 117120]
Details
117120 640 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
160 45° 36 46 73

Download the installation instructions of product: 117120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 125 [Code number: 116120]
Details
116120 320 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
125 45° 28 34 64

Download the installation instructions of product: 116120 HT bend

Chemical resistance of: Chemical resistance HT system

Ostendorf HT Bend 45° HTB, d 75 [Code number: 113120]
Details
113120 63 rub

Application purpose:

  • For drainage systems
  • For rainwater systems
  • For ventilation systems

Colour: gray

d α Z1 Z2 l1
mm mm mm mm mm
75 45° 16 12 51

Download the installation instructions of product: 113120 HT bend

Chemical resistance of: Chemical resistance HT system

See also