Logo
Ru| En
Loading

Anti-flood valves of Hutterer & Lechner with electronically controlled flap

Anti-flood valves of Hutterer and Lechner with electronically controlled flap can operate in fully automatic mode. These device do not create any obstacles for effluents because its flap is in open position in normal state, unlike mechanical analogs. It reduces likelihood accumulation of deposits and incrustations because of which flap can cease to tightly close, if there is backflow of effluents.

All HL anti-flood valves with electronically controlled flap are produced complete sets which include:

  • Body dual-chamber valve;
  • Electronic control unit which has control options and alarm system;
  • Flap cartridge motor driven with sensor
  • Connecting cables 5m.

Also the valves are equipped with special cleaning eye for maintenance of valves and for cleaning blockages.

HL anti-flood valve with electronically controlled flap is installed on the main pipeline and the electronic control unit should be mounted on wall close to the valve. Electronic control unit is connected to grounded receptacle. Also electronic control unit has a three-position switch for closing the flap if necessary.

The operating principle of the electric valve is simple: when reverse current of wastewater occurs and pipeline is filled with more than 70 percent, the electronic control unit set the light and color signals about the possibility of flooding. Then the flap closes automatically.

HL anti-flood valve with electronically controlled flap works from internal battery if the power supply is turned off. When power is restored, the battery is automatically shut down and then it switches to charging mode.

All HL anti-flood valve with electronically controlled flap are delivered completely ready for installation and operation, and they do not need adjustment.

Photo Name Article Price
Hutterer & Lechner Control block for HL 710.2ЕPC version II) with battery, control cable (6m) and mains cable [Code number: HL 0710E.0EPCN]
Details
HL 0710E.0EPCN 255 185 rub

Control block HL 0710E.0EPCN is designed for anti-flood valve HL 710.2EPC. The anti-flood valve is equipped with an electric drive, it protects against flooding due to the presence of two stainless steel flaps.

Length of control cable Equipment
m  
6 Control cable
Mains cable
Battery
Hutterer & Lechner emergency battery pack (rechargeable) for HL 710.2EPC [Code number: HL 0710E.A]
Details
HL 0710E.A 30 913 rub

Application purposes:

  • For anti-flood valves

Material: Ni-MH

Weight: 0,13 kg

Hutterer & Lechner control line extension, 20m [Code number: HL 0715E.0E]
Details
HL 0715E.0E 23 289 rub
Hutterer & Lechner Anti-flood valve with electronically controlled flap, additional flap and manual blocking, DN160 [Code number: HL 715.2EPC]
Details
HL715.2EPC 353 119 rub

Application purpose:

  • To reduce the likelihood of flooding basements and semi-basements where there is a risk of reverse current

Characteristics:

  • works in automatic mode;
  • working environment: drains (both non-faecal and faecal) with temperature from 0 to +40°C;
  • working pressure is 0-5 meters of water column;
  • the shutter consists of two chambers, and each has a shutter and an inspection hatch;
  • the first damper located in the direction of movement of the drains is equipped with an electric drive (opening time does not exceed 11 seconds);
  • the damper in the second chamber can be fixed in the closed position manually;
  • there is a backup power supply (working time: up to 168 hours);
  • shutter operation is controlled by an electronic control unit;
  • data on the state of the shutter can be transferred to the dispatching console (there are "dry" contacts for this, switching current 220V / 0.5A);
  • release type: smooth horizontal;
  • mounted with socket pipes made of PP and PVC;
  • power supply: 230V (+10%/-15%), 0.5A, 50Hz;
  • cable length is 6 m.

Attention! The sewer closure must be installed in a non-explosive environment. Also, it cannot be installed in sewer shafts on the street.

Technical characteristics

Diameter Main voltage Weight
DN, mm Volt gr
160 220 7973
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 280 635 9,38 0,068453

Documentation

Download data sheet: HL 715.2EPC Anti-flood valve HL 715.2EPC

Hutterer & Lechner Anti-flood valve with electronically controlled flap, additional flap and manual blocking, DN125 [Code number: HL 712.2EPC]
Details
HL 712.2EPC 334 253 rub

Anti-flood valve with electronically controlled flap HL 712.2EPC has diameter of 110 mm, it is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. It is equipped with additional stainless steel flap, cleaning eye and manual blocking. Inlet has socket, outlet is smooth. The valve is powered by network voltage of 220 V. For pipes made of PP or PVC.

Diameter Main voltage Weight
DN, mm Volt gr
125 220 6189
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
370 240 600 7,4 0,05328

Download data sheet: HL 712.2EPC Anti-flood valve HL 712.2EPC

Hutterer & Lechner Anti-flood valve with electronically controlled flap, additional flap and manual blocking, DN110 [Code number: HL 710.2EPC]
Details
HL 710.2EPC 314 716 rub

Anti-flood valve with electronically controlled flap HL 710.2EPC has diameter of 110 mm, it is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. It is equipped with additional stainless steel flap, cleaning eye and manual blocking. Inlet has socket, outlet is smooth. The valve is powered by network voltage of 220 V. For pipes made of PP or PVC.

Diameter Main voltage Weight
DN, mm Volt gr
110 220 6238
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
370 240 600 7,45 0,05328

Download data sheet: HL 710.2EPC Anti-flood valve HL 710.2EPC

Hutterer & Lechner Emergency supply accumulator 12V for HL710.2ЕРС [Code number: HL 0710EN.A]
Details
HL 0710EN.A 37 779 rub

Application purposes:

  • For anti-flood valves

Material: Ni-MH

Weight: 0,318 kg

Hutterer & Lechner Repair kit for anti-flood valve HL 710.2EPC [Code number: HL EPC 710.2]
Details
HL EPC 710.2 298 423 rub
Hutterer & Lechner Repair kit for anti-flood valve HL 715.2EPC [Code number: HL EPC 715.2]
Details
HL EPC 715.2 298 423 rub
Hutterer & Lechner Flap cartridge motor driven for HL710.2ЕРС and HL712.2EPC [Code number: HL 0710E.1E]
Details
HL 0710E.1E 17 120 rub

Application purposes:

  • For anti-flood valve with electronically controlled flap

Weight: 0,33 kg

Hutterer & Lechner Electronic control unit with interface [Code number: HL 0710E.0E]
Details
HL 0710E.0E 234 118 rub

Application purposes:

  • For anti-flood valves

Anti-flood valves of Hutterer and Lechner with electronically controlled flap works in automatic mode and practically does not require maintenance. It completely protects the room from possible flooding.

Hutterer & Lechner Flap cartridge motor driven with sensor [Code number: HL 0710E.4E]
Details
HL 0710E.4E 159 269 rub

Application area:

  • For anti flood valves

Weight: 2,19 kg

 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
210 330 330 2,463 0,022869000
Hutterer & Lechner Flap cartridge motor driven for HL715.2EPC [Code number: HL 0715E.1E]
Details
HL 0715E.1E 44 675 rub

Application purposes:

  • For motor driven

Weight: 0,47 kg

Hutterer & Lechner Electronic control unit with interface for HL 710.2ЕPC [Code number: HL 0710E.0EPC]
Details
HL 0710E.0EPC 285 499 rub

Application purposes:

  • For anti-flood valves

Weight: 1,357 kg

Hutterer & Lechner Engine electric drive of the valve [Code number: HL 0710E.4EN]
Details
HL 0710E.4EN 159 269 rub

See also