Anti-flood valves of Hutterer & Lechner

Anti-flood valves of Hutterer and Lechner is used with PP and PVC pipes, and with overflow wells. The valves are distinguished by configuration - they may be equiped with a flap, manual blocking, cleaning eye etc. Also the HL Company produces single or dual-chamber anti-flood valves and models for vertical mounting.

You should clean HL anti-flood valves regularly for their normal operation, and it is especially important in the spring before intensive melting of snow, and in the autumn before heavy rains begin.

HL anti-flood valves protect the premises not only against flooding, but also against rodents - animals cannot get into the house through closed flap.

Also HL anti-flood valves have high capacity.

Photo Name Article Price
Hutterer & Lechner Anti-flood valve with stainless steel flap and manual blocking, DN160 [Code number: HL 715.1]
Details
HL 715.1 63 312 rub

Anti-flood valve HL 715.1 with diameter of 160 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has automatic stainless steel flap, cleaning eye and manual blocking. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
160 3380
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
290 275 420 3,82 0,033495

Download data sheet: HL 715.1 Anti-flood valve HL 715.1

Hutterer & Lechner Anti-flood valve with 2 stainless steel flaps and manual blocking, DN160 [Code number: HL 715.2]
Details
HL 715.2 73 715 rub

Anti-flood valve HL 715.2 with diameter of 160 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has 2 automatic stainless steel flaps, cleaning eye and manual blocking. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
160 5870
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
295 290 635 7,19 0,05432425

Download data sheet: HL 715.2 Anti-flood valve HL 715.2

Hutterer & Lechner Anti-flood valve with stainless steel flap, DN200 [Code number: HL 720]
Details
HL 720 51 034 rub

Anti-flood valve HL 720 with diameter of 200 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has automatic stainless steel flap and cleaning eye. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
200 4060
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
295 290 465 4,7 0,03978075

Download data sheet: HL 720 Anti-flood valve HL 720

Hutterer & Lechner Anti-flood valve with flap and socket for plastic pipes, DN200 [Code number: HL 720.0]
Details
HL 720.0 45 926 rub

Anti-flood valve HL 720.0 with diameter of 200 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has automatic stainless steel flap and socket for plastic pipes. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
200 1560
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS

Download data sheet: HL 720.0 Anti-flood valve HL 720.0

Hutterer & Lechner Anti-flood valve with stainless steel flap and manual blocking, DN200 [Code number: HL 720.1]
Details
HL 720.1 77 525 rub

Anti-flood valve HL 720.1 with diameter of 200 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has automatic stainless steel flap, cleaning eye and manual blocking. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
200 3680
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
295 290 465 4,32 0,03978075

Download data sheet: HL 720.1 Anti-flood valve HL 720.1

Hutterer & Lechner Anti-flood valve with 2 stainless steel flap and manual blocking, DN200 [Code number: HL 720.2]
Details
HL 720.2 121 283 rub

Anti-flood valve HL 720.2 with diameter of 125 mm is designed for installation in the basement. The valve separates the internal sewerage system from the main sewerage, and it is used for prevention of flooding. The valve remains operational at temperatures up to +60 °C. It has 2 automatic stainless steel flaps, cleaning eye and manual blocking. Locking flap is made of high-quality stainless steel. For pipes made of PP or PVC.

Diameter Weight
DN, mm gr
200 6170
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
295 290 635 7,49 0,05432425

Download data sheet: HL 720.2 Anti-flood valve HL 720.2

Hutterer & Lechner Flap seal for external down pipes, DN110 [Code number: HL 603/1]
Details
HL 603/1 13 690 rub

Flap seal HL 603/1 is equipped with a mechanical device which is prevents foul air from rising up down pipes. The flap seal with diameter 110 mm weighs 940 grams. It is made of polypropylene. Capacity is 6 l/s.

Diameter Capacity Material Weight
DN, mm l/s   gr
110 6 polypropylene 940
Hutterer & Lechner Casing gasket for HL710 [Code number: HL 01078D]
Details
HL 01078D 2 968 rub

Application area:

  • For anti flood valves

Weight: 0,042 kg

Hutterer & Lechner Floor drain body with backwater stop, 3 inlets DN40/50 and pre-installed lot cover, horizontal, DN75/110 [Code number: HL 70K-3020]
Details
HL 70K-3020 13 625 rub

Floor drain body HL 70K-3020 is equipped with flange, trap, backwater stop (automatically or manual), cleaning eye and 3 inlets DN40/50. It has horizontal outlet DN75/110. For series HL 3020. Comes with pre-installed lot cover.

Material Diameter Weight
  DN, mm kg
polyethylene 75/110 0,73
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
210 330 330 1,043 0,022869
Hutterer & Lechner Anti-flood valve as HL 710.2, but without casing cover HL 0710.31E [Code number: HL 710.2-K]
Details
HL 710.2-K 29 518 rub

See also