Logo
Ru| En

Office: M. Baumanskaya

Warehouse: Lenin Hills

Loading

Roof penetrations Fachmann

Roof penetrations Fachmann are designed for the hermetic installation of pipes, cables, shield supports, flagpoles, etc. through the roof. They are made of PVC and EPDM.

Roof penetrations are suitable for bitumen roofing, provide a reliable connection and a large sealing surface area. Easy to install. They are resistant to temperature changes and atmospheric influences, as well as elasticity. They do not lose technical properties in either heat or cold.

They are suitable for flat and flat roofing.

Photo Наименование Article Цена
Fachmann Roof penetration EPDM №1 (00-40) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.109]
Details
01.109 1 817 rub
Fachmann Roof penetration EPDM №2 (50-60) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.110]
Details
01.110 1 853 rub
Fachmann Roof penetration EPDM №3 (75-90) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.111]
Details
01.111 2 030 rub
Fachmann Roof penetration EPDM №4 (110-125) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.112]
Details
01.112 2 319 rub
Fachmann Roof penetration EPDM №5 (130-140) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.113]
Details
01.113 2 444 rub
Fachmann Roof penetration PVC №1 (20-50) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.114]
Details
01.114 811 rub
Fachmann Roof penetration PVC №2 (50-90) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.115]
Details
01.115 1 162 rub
Fachmann Roof penetration PVC №3 (110-160) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.116]
Details
01.116 1 784 rub

Fachmann PVC roofing No. 3 (110-160) ensures the installation of antennas, wires, and flagpoles laid through the roof. The flange is made of polyvinyl chloride. The material is characterized by improved elasticity, which is necessary when installed in conditions of negative temperature.

Main Features

  • The material is PVC.
  • Mounting diameter - 110-160 mm, height - 170 mm, flange diameter - 370 mm.
  • The operating temperature range is from -50° to +150 °C.

The design of the cone-shaped Fachmann sinking form factor is made in the form of successively narrowing ledges, which allows the element to be operated with almost any slope of the roof.

Sinking is used to preserve the tightness of waterproofing materials of a flat, sloping roof when installing cables, converters, and advertising structures. Maintains maximum tight contact of water mains, air exchange systems, heating pipes and other communications with roofing materials.

Fachmann PVC No. 3 (110-160) penetration is resistant to the influence of atmospheric factors, temperature changes, and does not lose its technical properties in extreme heat and frost. A fully ready-to-install part will speed up the installation of the roof and reduce labor costs. Due to its high elasticity, full water resistance is guaranteed, regardless of the location of the structure.

Technical specifications

Height of roof penetration Flange diameter Material
mm mm  
175 400 PVC

See also