Hutterer Lechner roof drains with vertical outlet vary by configuration. Thus, they can be equipped with a domed plastic grate, insulated drain body, electrically heating, a clamping ring etc. Some models have an universal vertical connection - it allows to connect them with various kinds of pipes, namely steel, plastic and cast iron pipes. The roof drains HL 62 and HL 63 can be used on non-operated and operated roofs. Capacity of the roof drains can be up to 14.1 l/s. The company produces the roof drains with diameters from 75 mm to 160 mm.
Also the HL company produces the special roof drains which facilitate repair of gutter system and reduce cost of repair. The special design of the repair roof drains does not need dismantling of old roof drain when stormwater system collapsed - HL repair roof drains can be installed directly into previous device. Also the repair roof drains are used for replacement of waterproofing layer. They have long outlet pipe - it compensate different heights of stormwater pipes.
Photo | Name | Article | Price | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated, vertical, DN160 [Code number: HL 62.1BH/5]
Details
|
HL 62.1BH/5 | 28 168 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting example Technical characteristics
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1BH/5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN75 [Code number: HL 62.1BH/7]
Details
|
HL 62.1BH/7 | 28 168 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting example Technical characteristics
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1BH/7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PVC collar, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1BP/1]
Details
|
HL 62.1BP/1 | 26 489 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1BP/1 is equipped with insulated drain body, PVC collar, cut-to-size grate frame 19 - 68 mm and stainless steel grate 137 x 137 mm. The flat-roof drain has vertical outlet DN110. It weighs 1722 grams. Capacity is 6,00 l/s.
Material of spare parts
Packaging data (carton)
Download example of use: Flat-roof drain HL 62.1BP/1 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PVC collar, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1BP/2]
Details
|
HL 62.1BP/2 | 26 489 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1BP/2 is equipped with insulated drain body, PVC collar, cut-to-size grate frame 19 - 68 mm and stainless steel grate 137 x 137 mm. The flat-roof drain has vertical outlet DN125. It weighs 1717 grams. Capacity is 6,00 l/s.
Material of spare parts
Packaging data (carton)
Download example of use: Flat-roof drain HL 62.1BP/2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PVC collar, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1BP/5]
Details
|
HL 62.1BP/5 | 26 489 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1BP/5 is equipped with insulated drain body, PVC collar, cut-to-size grate frame 19 - 68 mm and stainless steel grate 137 x 137 mm. The flat-roof drain has vertical outlet DN160. It weighs 1751 grams. Capacity is 6,00 l/s.
Material of spare parts
Packaging data (carton)
Download example of use: Flat-roof drain HL 62.1BP/5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PVC collar, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1BP/7]
Details
|
HL 62.1BP/7 | 26 489 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1BP/7 is equipped with insulated drain body, PVC collar, cut-to-size grate frame 19 - 68 mm and stainless steel grate 137 x 137 mm. The flat-roof drain has vertical outlet DN75. It weighs 1743 grams. Capacity is 6,00 l/s.
Material of spare parts
Packaging data (carton)
Download example of use: Flat-roof drain HL 62.1BP/7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PP-flange and heating (10-30W/230V), vertical, DN110 [Code number: HL 62.1F/1]
Details
|
HL 62.1F/1 | 19 432 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1F/1 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN110. The body and leaf catcher are made of polypropylene. It weighs 1426 grams. Capacity is 7,85 l/s. Diameter of the leaf catcher is 180 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PP-flange and heating, vertical, DN125 [Code number: HL 62.1F/2]
Details
|
HL 62.1F/2 | 19 432 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1F/2 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN125. The body and leaf catcher are made of polypropylene. It weighs 1421 grams. Capacity is 10,75 l/s. Diameter of the leaf catcher is 180 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with PP-flange and heating (10-30W/230V), vertical, DN75 [Code number: HL 62.1F/7]
Details
|
HL 62.1F/7 | 19 432 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flat-roof drain HL 62.1F/7 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN75. The body and leaf catcher are made of polypropylene. It weighs 1447 grams. Capacity is 7,4 l/s. Diameter of the leaf catcher is 180 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with PP collar, heating element U=230V, power 10-30W, vertical, DN110 [Code number: HL 62.1FSafe/1]
Details
|
HL 62.1FSafe/1 | 36 126 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain HL 62.1FSafe/1 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with PP collar heating element U=230V, power 10-30W, vertical, DN125 [Code number: HL 62.1FSafe/2]
Details
|
HL 62.1FSafe/2 | 36 126 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain HL 62.1FSafe/2 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with PP collar heating element U=230V, power 10-30W, vertical, DN75 [Code number: HL 62.1FSafe/7]
Details
|
HL 62.1FSafe/7 | 36 126 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain HL 62.1FSafe/7 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1H/1]
Details
|
HL 62.1H/1 | 22 285 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting tips:
Technical details
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1H/1 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN125 [Code number: HL 62.1H/2]
Details
|
HL 62.1H/2 | 22 285 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting tips:
Technical details
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1H/2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated, vertical, DN160 [Code number: HL 62.1H/5]
Details
|
HL 62.1H/5 | 22 285 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting tips:
Technical details
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1H/5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN75 [Code number: HL 62.1H/7]
Details
|
HL 62.1H/7 | 22 285 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application purpose:
Characteristics:
Mounting tips:
Technical details
Material of spare parts
Packaging data (carton)
DocumentationDownload example of use: Flat-roof drain HL 62.1H/7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar heating element U=230V, power 10-30W, vertical, DN110 [Code number: HL 62.1HSafe/1]
Details
|
HL 62.1HSafe/1 | 39 941 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.
Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m. Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.
Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions. Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar, heating element U=230V, power 10-30W, vertical, DN125 [Code number: HL 62.1HSafe/2]
Details
|
HL 62.1HSafe/2 | 39 941 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.
Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m. Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.
Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions. Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar, heating element U=230V, power 10-30W, vertical, DN160 [Code number: HL 62.1HSafe/5]
Details
|
HL 62.1HSafe/5 | 39 941 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.
Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m. Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.
Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions. Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.
Material of spare parts
Packaging data (carton)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar heating element U=230V, power 10-30W, vertical, DN75 [Code number: HL 62.1HSafe/7]
Details
|
HL 62.1HSafe/7 | 39 941 rub | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.
Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m. Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.
Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions. Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.
Material of spare parts
Packaging data (carton)
|