Roof drain for emergency drain with electric heating, with vertical outlet, with flange, with the possibility of adjusting the thickness of the water layer from 28 to 68 mm.
Diameter | Mounting height | Weight |
---|---|---|
DN mm | mm | kg |
110 | 100 | 3,174 |
Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m.
Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.
DIN EN 1253 | 5 | 15 | 25 | 35 | 45 | 55 | 65 |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | mm |
4,5 (35 mm) | 0,9 | 3,8 | 6,4 | 9,1 | 12,2 | 15,8 | 20,1 |
Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions.
Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.
DIN EN 1253 | 5 | 15 | 25 | 35 | 45 | 55 | 65 |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | mm |
4,5 (35 mm) | 0,9 | 3,2 | 5,5 | 8,1 | 9,6 | 10,1 | 10,5 |
Leaf strainer | Clamping ring | Hexagon nut | Body |
---|---|---|---|
polypropylene | stainless steel | stainless steel | polypropylene |
Height | Width | Depth | Weight | Volume |
---|---|---|---|---|
mm | mm | mm | kg | m3 |
300 | 385 | 385 | 3,974 | 0,0444675 |
Hutterer & Lechner Extension with stainless steel clamping ring, 300 mm / d 125 [Code number: HL 65] (Russia)
Hutterer & Lechner Extension with PP-flange for welding of FPO-sheeting, based on PP, 345mm / d125 [Code number: HL 65F]
Hutterer & Lechner Extension with bitumen membrane d 500 mm, 300 mm / d 125 [Code number: HL 65H]