Logo
Ru| En
Loading

Fachmann Roof aerator, PVC, for PVC membranes welded homogeneously with hot air, for all climatic regions, DN - 75, height 375mm [Code number: 01.171]

Article: 01.171
Price: 812 rub

FACHMANN A75x375 PVC roofing aerator is a device for removing excess steam from roofs with free air circulation between the insulation and the outer coating. It is suitable for outdated structures that are updated with PVC membranes. The main area of use is flat roofs of buildings with a high moisture content. It is installed evenly over the entire area at the rate of one unit per 100m2 in the highest areas of the roofing carpet.

The aerator helps to reduce the moisture content of the thermal insulation material and other layers of the roof. As a result, the period of operation of the structure increases, and a favorable microclimate is maintained in the interior spaces.

Main Features

The FACHMANN A75x375 mm PVC 01.171 roof aerator structurally includes a rack and a hood. The stand is made of durable PVC, the hood is made of frost-resistant polypropylene.

To give the working position, it is welded to the membrane material.

The operating temperature range of the aerator is from -40C to +80C.

It is adapted to any direction of the air environment.

Technical specifications

Diameter Diameter of the aerator rack Outlet height< Material Type of waterproofing
mm mm mm    
75 275 375 PVC Polymer

Documentation

Download: 01.171 Passport 01.171

For more details

01.109

Fachmann Roof penetration EPDM №1 (00-40) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.109]

01.110

Fachmann Roof penetration EPDM №2 (50-60) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.110]

01.111

Fachmann Roof penetration EPDM №3 (75-90) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.111]

01.112

Fachmann Roof penetration EPDM №4 (110-125) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.112]

01.113

Fachmann Roof penetration EPDM №5 (130-140) for sealed installation of pipes, supports of billboards, flagpoles, cables, etc. through the bitumen roof [Code number: 01.113]

01.114

Fachmann Roof penetration PVC №1 (20-50) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.114]

01.115

Fachmann Roof penetration PVC №2 (50-90) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.115]

01.116

Fachmann Roof penetration PVC №3 (110-160) for tight connection of water, heating pipelines, air ducts and other structural elements to roofing material [Code number: 01.116]

Back to group page