Logo
Ru| En
Loading

VALTEC Balancing valves

VALTEC Balancing valves are designed for hydraulic integration of different branches (stand-pipes) of water based heating systems. Also, balancing valves can be used in water pipelines - they limit consumption by groups of users (devices) and balance recirculation pipelines of hot water supply.

Nominal valve pressure is 16 bar, automatic flow rate stabilizer - 25 bar.

Maximum fluid temperature +120 °C.

Photo Name Article Price
VALTEC Automatic valve body plug, size 3 (50 mm cast iron) [Code number: VT.145.D.03]
Details
VT.145.D.03 4 524 rub
VALTEC Differential pressure regulator cartridge adjustable with control valve, size 1. 3-17 kPa 9-6 [Code number: VT.146.G.0117]
Details
VT.146.G.0117 8 802 rub
VALTEC Differential pressure regulator cartridge adjustable, size 1. 3-35 kPa (ADP.1) [Code number: VT.146.G.0135]
Details
VT.146.G.0135 8 208 rub
VALTEC Direct-acting temperature controller, d - 1/2" [Code number: VT.348.N.04]
Details
VT.348.N.04 3 462 rub
VALTEC Closing section with manual air vent (mounting template 3/4"EK -50 mm.) [Code number VT.AVF02.N.2E04]
Details
VT.AVF02.N.2E04 713 rub
VALTEC Cartridge with open setting for S body, 17-210 kPa, 100-412 l/h, black/white, d - 1/2" or 3/4" (590116) [Code number: VT.PICC.G.020]
Details
VT.PICC.G.020 6 650 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Size: 1/2" or 3/4";
  • Color: black/white;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 17-210 kPa;
  • Flow range: 100-412 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.020 VALTEC Cartridge with open setting

VALTEC Cartridge with open setting for S body, 17-210 kPa, 157-609 l/h, green/white, d - 1/2" or 3/4" (590117) [Code number: VT.PICC.G.021]
Details
VT.PICC.G.021 6 916 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Size: 1/2" or 3/4";
  • Color: green/white;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 17-210 kPa;
  • Flow range: 157-609 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.021 VALTEC Cartridge with open setting

VALTEC Cartridge with open setting for S body, 17-200 kPa, 276-825 l/h, red/white, d - 1/2" or 3/4" (590118) [Code number: VT.PICC.G.022]
Details
VT.PICC.G.022 6 684 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Size: 1/2" or 3/4";
  • Color: red/white;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 17-200 kPa;
  • Flow range: 276-825 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.022 VALTEC Cartridge with open setting

VALTEC cartridge with open adjustment., 30-400 kPa, 406-1270 l/h, red (590119) [Code number: VT.PICC.G.023]
Details
VT.PICC.G.023 6 809 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Color: red;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 30-400 kPa;
  • Flow range: 406-1270 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.023 VALTEC Cartridge with open setting

VALTEC cartridge with open adjustment., 30-400 kPa, 138-615 l/h, black (590120) [Code number: VT.PICC.G.024]
Details
VT.PICC.G.024 6 547 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Color: black;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 30-400 kPa;
  • Flow range: 138-615 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.024 VALTEC Cartridge with open setting

VALTEC Cartridge with open setting for S body, 30-400 kPa, 238-896 l/h, green/grey, d - 1/2" or 3/4" (590121) [Code number: VT.PICC.G.025]
Details
VT.PICC.G.025 6 650 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Size: 1/2" or 3/4";
  • Color: green/grey;
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 30-400 kPa;
  • Flow range: 238-896 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.025 VALTEC Cartridge with open setting

VALTEC Cartridge with integrated control valve for S body, 16-200 kPa, 37-575 l/h, grey, d - 1/2" or 3/4" (590123) [Code number: VT.PICC.G.035]
Details
VT.PICC.G.035 13 064 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • Works as part of general house automation, which maintains the temperature in the premises at a given level;
  • There is a built-in control valve;
  • The built-in valve is controlled by a servo;
  • Color: grey;
  • Size: 1/2" or 3/4";
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 16-200 kPa;
  • Flow range: 37-575 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.035 VALTEC Cartridge with integrated control valve

VALTEC Cartridge with integrated control valve for S body, 30-400 kPa, 64-1110 l/h, black, d - 1/2" or 3/4" (590124) [Code number: VT.PICC.G.036]
Details
VT.PICC.G.036 13 064 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • Works as part of general house automation, which maintains the temperature in the premises at a given level;
  • There is a built-in control valve;
  • The built-in valve is controlled by a servo;
  • Color: black;
  • Size: 1/2" or 3/4";
  • Suitable for G0 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 30-400 kPa;
  • Flow range: 64-1110 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.036 VALTEC Cartridge with integrated control valve

VALTEC Cartridge with open setting for M body, 17–400 kPa, 535-5830 l/h, black/grey, d - 1" (590122) [Code number: VT.PICC.G.125]
Details
VT.PICC.G.125 12 557 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • The cartridge is used in conjunction with the VT.PICV body - it is screwed into the body instead of a mounting plug (the cartridge is pre-configured). Due to this, in case of adding or removing heaters or branches, it will not be necessary to dismantle the stabilizer body - it will be enough to replace the cartridge;
  • Type: with open setting;
  • Size: 1";
  • Color: black/grey;
  • Suitable for G1 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 17-400 kPa;
  • Flow range: 535-5830 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.125 VALTEC Cartridge with open setting

VALTEC Cartridge with integrated control valveg for M body, 16-400 kPa, 865-4630 l/h, black, d - 1" (590125) [Code number: VT.PICC.G.136]
Details
VT.PICC.G.136 25 863 rub

Purpose of application:

  • For automatic flow stabilizer VT.PICV
  • For adjusting the flow rate in modern heating systems
  • For risers of single-pipe water heating

Characteristics:

  • Works as part of general house automation, which maintains the temperature in the premises at a given level;
  • There is a built-in control valve;
  • The built-in valve is controlled by a servo;
  • Color: black;
  • Size: 1";
  • Suitable for G1 case;
  • Nominal pressure: 25 bar;
  • Operating temperature ranges from -20 to +120 °C;
  • Pressure drop range: 16-400 kPa;
  • Flow range: 865-4630 liters/hour;
  • Average full service life: 15 years.

Documentation

Download product data sheet: VT.PICC.G.136 VALTEC Cartridge with integrated control valve

VALTEC Regulated dynamic automatic flow regulator, female-female, d - 1/2" (590065) [Code number: VT.PICV.G.04]
Details
VT.PICV.G.04 3 360 rub
VALTEC Regulated dynamic automatic flow regulator, female-female, d - 3/4" (590066) [Code number: VT.PICV.G.05]
Details
VT.PICV.G.05 3 607 rub
VALTEC Regulated dynamic automatic flow regulator, female-female, d - 1" (590141) [Code number: VT.PICV.G.06]
Details
VT.PICV.G.06 10 760 rub
VALTEC Regulated dynamic automatic flow regulator, female-female, d - 1" (590067) [Code number: VT.PICV.G.16]
Details
VT.PICV.G.16 10 726 rub
VALTEC Regulated dynamic automatic flow regulator, female-female, d - 1 1/4" (590068) [Code number: VT.PICV.G.17]
Details
VT.PICV.G.17 10 124 rub

See also