Photo
Наименование
Article
Цена
[NO LONGER PRODUCED] - Ostendorf Double branch 45°, d - 50/50 [Code number: 904018]
Details
904018
132 rub
Application purpose:
For drainage systems
For branching pipeline
Characteristics:
PP
Max. working temperature +95°C
Main advantages of Ostendorf pipelines:
Low weight
Strength
Reliability
Durability
Low noise
Resistance to high temperatures
Efficiency
Round access pipe PAM-GLOBAL® S
Details
Nominal internal diameter
H
D1
D2
L
Weight
Code number
DN
kg
50
64
53
105
190
2,3
179191
70*
69
73
125
210
2,9
155799
80
73
73
125
210
3,2
179647
100
84
104
159
260
5,0
179192
125
152
202
280
7,0
280010
150
180
243
320
9,8
280012
200
180
243
360
12,9
280013
250
180
274
380
18,7
280014
300
180
326
400
25,0
280015
Dimensions are presented in mm
*Diameter 80 gradually replace diameter 70
Branch trap PAM-GLOBAL® S
Details
Branch traps PAM-GLOBAL® S with nominal diameter of 50-200 mm can be mounted on a vertical and horizontal pipeline (the vertical pipeline must be fixed). The branch trap is installed vertically to maintain a sufficient depth of the water seal. The branch trap can be installed both to pipeline-collector and to pressure riser. On the branch trap body are printed arrows which are indicating the direction of flow.
Nominal internal diameter
I
h
X1
X2
X3
X4
W
Weight
Code number
DN
kg
50
190
250
182
68
122
68
60
2,9
156420
70*
265
293
200
93
172
93
60
5,0
156521
80
265
293
200
93
172
93
60
5,9
176714
100
325
392
282
110
215
110
100
9,5
156668
125
390
446
316
130
260
130
100
14,4
156801
150
470
493
348
145
325
145
100
21,8
156912
200
600
600
420
180
400
200
100
38,4
157018
Dimensions are presented in mm
*Diameter 80 gradually replace diameter 70
Installation examples:
Blank end PAM-GLOBAL® S
Details
Nominal internal diameter
L
Weight
Code number
DN
mm
kg
50
30
0,3
155747
70*
35
0,4
155776
80
35
0,5
176700
100
40
0,8
155809
125
45
1,2
155865
150
50
1,7
155898
200
60
3,2
155928
250
70
5,9
155945
300
80
10,0
155957
* Diameter 80 gradually replace diameter 70
Blank end PAM-GLOBAL® Plus
Details
Nominal internal diameter
L
Weight
Code number
DN
mm
kg
50
30
0,25
155197
80
35
0,45
176783
100
40
0,80
155231
125
45
1,20
155257
150
50
1,70
155273
200
60
3,20
155287
250
70
5,90
155477
300
80
10
155494
Eccentric reducer PAM-GLOBAL® S
Details
Nominal internal diameter
A
L
t1
t2
Weight
Code number
DN
kg
70x50
10
75
35
30
0,5
155763
80x50*
13
80
35
30
0,7
176727
100x50
25
80
40
30
0,8
155764
100x70*
16
85
40
35
0,9
155801
100x80
14
90
40
35
1,0
176728
125x50
38,5
85
45
30
1,5
155765
125x70*
28,5
90
45
35
1,3
155802
125x80
26
95
45
35
1,3
176730
125x100
12,5
95
45
40
1,6
155842
150x50
51
95
50
30
1,9
155766
150x70*
41
100
50
35
2,0
155803
150x80
39
100
80
35
2,0
176732
150x100
25
105
50
40
2,0
155843
150x125
12,5
110
50
45
2,0
155892
200x75
64
115
43
72
3,8
156532
200x100
50
115
60
40
3,6
155844
200x125
37,5
120
60
45
3,8
155893
200x150
25
125
60
50
4,3
155922
250x100
82
125
45
82
6
156690
250x150
57
140
70
50
6,8
155923
250x200
32
145
70
60
7,0
155942
300x100
108
140
45
95
9,4
156692
300x150
83
150
80
50
10,7
155924
300x200
58
160
80
60
11,4
155943
300x250
26
170
80
70
12,4
155955
400x300
52
200
100
100
19,6
157163
Dimensions are presented in mm
*Diameter 80 gradually replace diameter 70
Round access pipe PAM-GLOBAL® Plus
Details
Nominal internal diameter
H
D1
D2
L
Weight
Code number
DN
kg
50
64
53
105
190
2,3
179348
70
179349
80
73
78
134
220
3,2
179648
100
84
104
159
260
5,0
179350
Dimensions are presented in mm
Bend PAM-GLOBAL® Plus 15˚
Details
Nominal internal diameter
X
Weight
Code number
DN
mm
kg
50
40
0,47
155202
80
45
0,68
176781
100
50
1,15
155237
125
60
1,77
155262
150
65
2,40
155278
200
80
4,40
173774
400
100
21,40
on order
PAM-GLOBAL® Plus Double branch 45°
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
DN
mm
mm
mm
mm
kg
100x100x100
70
190
190
260
4,6
155384
125x125x125
65
240
240
305
7,9
155411
150x150x150
90
265
265
355
11,8
155445
200x200x200
115
340
340
455
18,4
155473
45˚ single branch PAM-GLOBAL® Plus
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
DN
kg
50x50
50
135
135
185
1,35
155213
80x50
45
135
135
180
1,60
176740
80x80
60
155
155
215
2,20
176742
100x50
35
165
165
200
2,40
155245
100x80
50
170
170
220
2,75
176743
100x100
70
205
205
275
3,8
155255
125x50
20
185
185
205
3,24
155264
125x80
51
189
189
240
4,20
176784
125x100
60
220
220
280
5,60
155267
125x125
80
240
240
320
5,70
155271
150x80
50
220
220
255
5,30
176785
150x100
55
240
240
295
6,12
155281
150x125
70
255
255
325
7,00
155282
150x150
90
265
265
355
8,75
155285
200x80
20
240
240
260
7,34
176786
200x100
40
265
265
305
8,64
155291
200x125
55
280
280
335
11,60
155292
200x150
75
300
300
375
11,43
155293
200x200
115
340
340
455
16,78
155295
250x150
55
350
350
405
22
208730
250x200
90
390
390
480
22,4
155483
250x250
130
430
430
580
29
155490
300x250
115
465
465
580
37,6
155500
300x300
155
505
505
660
46,3
155507
400x300
105
555
555
660
56,4
155510
400x400
190
645
645
835
98
on order
Dimensions are presented in mm
PAM-GLOBAL® S Iron flange fitting for roof penetration
Details
To reliable the installation ventilation pipes through the roof, you should use the specially designed element - PAM-GLOBAL® S Iron flange fitting for roof penetration.
Profile seal is inserted between the pipe and flange fitting for roof penetration so that the flange fitting is waterproof. The flange fitting is produced with sealing ring made of EPDM or NBR.
The first flange fitting is installed under the roof insulation layer, and the second flange fitting - above the roof insulation layer. Accordingly the first flange fitting "clamps" еру vapor barrier and the second flange fitting "clamps" waterproofing layer, be it polymer or bituminous.
Nominal internal diameter
D
d
Lk Ø
h
Weight
Code number
DN
mm
mm
mm
mm
kg
80
286
135
215
60
6,1
205922
100
324
158
246
60
6,6
205924
125
349
188
271
60
7,5
205925
PAM-GLOBAL® S Double branch 45°
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
DN
mm
mm
mm
mm
kg
100x100x100
70
190
190
260
5,3
156709
125x100x100
60
220
220
280
6,3
257729
125x125x125
75
230
230
305
7,5
156817
150x100x100
55
225
225
280
7,3
156865
150x150x150
90
270
270
360
12,0
156936
200x200x200
115
340
340
455
18,4
157034
45˚ single branch PAM-GLOBAL® S
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
DN
kg
50x50
50
135
135
185
1,4
155769
70x50*
40
150
150
190
1,5
155789
80x50
45
135
135
180
1,6
173786
70x70*
55
160
160
215
2,1
155806
80x80
60
155
155
215
2,2
173787
100x50
35
165
165
200
2,4
155828
100x70*
50
185
185
235
2,7
155831
100x80
50
170
170
220
2,8
173788
100x100
70
205
205
275
3,8
155857
125x50
20
185
185
205
3,2
155877
125x70*
40
200
200
240
4,1
155879
125x80
45
200
195
240
4,2
176716
125x100
60
220
220
280
5,6
155882
125x125
80
240
240
320
5,7
155895
150x70*
30
215
215
245
5,2
155910
150x80
50
220
220
255
5,9
176733
150x100
55
240
240
295
6,1
155912
150x125
70
255
255
325
7,0
155914
150x150
90
265
265
355
8,8
155926
200x70*
15
240
240
255
7,2
155934
200x80
20
240
240
260
7,3
176734
200x100
40
265
265
305
8,6
155935
200x125
55
280
280
335
11,4
155936
200x150
75
300
300
375
11,6
155937
200x200
115
340
340
455
16,8
155944
250x100
15
315
315
330
13,6
155949
250x125
35
335
335
370
16,0
155950
250x150
55
350
350
405
17,3
155951
250x200
90
390
390
480
22,4
155952
250x250
130
430
430
560
29,0
155956
300x100
5
345
345
350
19,3
155961
300x125
15
360
360
375
21,0
155962
300x150
35
380
380
415
28,0
155963
300x200
70
440
415
485
28,1
155964
300x250
115
465
465
580
37,6
155965
300x300
115
505
505
660
46,3
155968
400x300
105
555
555
660
56,4
157178
400x400
190
645
645
835
98
157185
Dimensions are presented in mm
* Diameter 80 gradually replace diameter 70
Hutterer & Lechner Tubular trap with appliance hose connector and ball-joint outlet, DN40x1 1/2' [Code number: HL 100/40]
Details
HL 100/40
2 475 rub
Tubular trap HL 100/40 DN 40 horizontal is made of polypropylene. The device is equipped with ball-joint outlet and appliance hose connector 6/4". In addition, the trap can connect to the washing machine or dishwasher, which uses input 3/4".
Diameter
Material
Weight
DN, mm
gr
40
polypropylene
260
Documentation Download data sheet: Tubular trap HL 100/40
Download example of product installation: Tubular trap HL 100/40
Hutterer & Lechner Wash-basin trap with rosette, DN32x1 1/4' [Code number: HL 132/30]
Details
HL 132/30
1 831 rub
HL 132/30 wash-basin trap DN32 x 1 1/4' horizontal is connected to a wash basin. It is made of polypropylene and has a weight is 180 grams. The wash-basin trap can connect to a dishwasher or washing machine, height of the dip tube is adjusted. HL 132/30 is equipped with a decorative rosette.
Diameter
Material
Weight
DN, mm
gr
32
polypropylene
180
Download data sheet: Wash-basin trap HL 132/30
Hutterer & Lechner Bath tub trap with ball-joint, DN40/50x1 1/2' [Code number: HL 500-6/4]
Details
HL 500-6/4
2 350 rub
Application area:
Characteristics:
Material: PP/PE
Dimension: DN40/50 x 6/4"
Capacity: 0,83 l/s
Installation height: 93 mm
Weight: 0,17 kg
Packaging data (PE-bag)
Height
Width
Depth
Weight
Volume
mm
mm
mm
kg
m3
80
100
252
0,176
0,002016000
Documentation
Download example of product installation: Bath tub trap HL 500-6/4
WC bend 90˚ PAM-GLOBAL® S
Details
Nominal internal diameter
X1
X2
X3
X4
Weight
Code number
DN
mm
mm
mm
mm
kg
80
145
55
50
105
2,0
176725
100
150
44
40
84
2,6
155852
Bend PAM-GLOBAL® S 15˚
Details
Nominal internal diameter
X
Weight
Code number
DN
mm
kg
50
40
0,5
155752
70*
45
0,6
155781
80
45
0,7
176702
100
50
1,2
155816
125
60
1,8
155870
150
65
2,4
155903
200
80
4,4
155932
*Diameter 80 gradually replace diameter 70
68˚ double branch PAM-GLOBAL® S
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
Old code number
DN
kg
50x50x50
60
85
85
145
1,2
156437
75x75x75
70
110
110
180
2,3
156546
100x75x75
70
125
115
185
3
156609
100x100x100
85
130
130
215
3,4
156707
155859
125x100x100
85
145
140
225
4,5
156766
155875
125x125x125
100
155
155
255
5,5
156815
150x125x125
100
170
165
265
6,6
156867
150x150x150
115
180
180
295
8,2
156934
200x150x150
110
210
200
310
10,7
156978
200x200x200
140
225
225
365
14
157032
Dimensions are presented in mm
88˚ single branch PAM-GLOBAL® S with angle of entry 45˚
Details
Nominal internal diameter
X1
X2
X3
L
Weight
Code number
DN
kg
50x50
79
80
66
145
1,0
155767
70x50*
83
90
72
155
1,3
155787
80x50
85
90
75
160
1,4
176718
70x70*
97
95
83
180
1,7
155804
80x80
95
95
85
180
1,8
176719
100x50
94
105
76
170
2,1
155827
100x70*
102
110
88
190
2,3
155829
100x80
100
110
90
190
2,4
176720
100x100
115
115
105
220
2,7
155855
125x50
98
120
82
180
2,8
155876
125x70*
107
125
93
200
2,9
155878
125x80
105
125
100
205
3,0
176722
125x100
125
130
110
235
4,2
155880
125x125
137
135
123
260
5,0
155894
150x50
100
140
100
200
3,9
155908
150x70*
115
140
100
215
4,4
155909
150x80
115
140
105
220
4,4
176723
150x100
130
145
115
245
4,9
155911
150x125
147
150
128
275
6,1
155913
150x150
158
155
142
300
8,5
155925
200x100
145
175
125
270
8,8
156980
200x200
193
183
172
365
10,4
157024
250x250
240
243
228
455
19,5
157102
300x300
265
265
265
530
35
157165
400x400
370
370
314
684
67
170732
Dimensions are presented in mm
* Diameter 80 gradually replace diameter 70