OGNEZA-PM-K Cable penetration, red, d 80 (price on request) [Code number: 1r0124]
Details
|
1r0124 |
|
Application purpose:
- To block the spread of fire along cable lines
- For installation in places of passage of cables, pipelines of engineering systems, technological pipelines
Characteristics:
- due to the fact that the coupling body is detachable, it can be mounted on an already laid cable line;
- metal parts are powder coated to reduce corrosion (colour: red);
- triggers approximately 15 seconds after the temperature rises to +150°C;
- expansion coefficient: not less than 900%;
- the fire resistance limit is 180 minutes;
- service life: 30 years (at temperatures from -50 to +80°C).
Installation recommendations:
- the thickness of the walls where the cable passage is mounted must be at least 150 mm;
- the cable sleeve is installed on both sides in a metal sleeve in the ceiling along the cable lines. If there is no sleeve, installation is possible in a hole sealed with mineral wool;
- fastened with anchor bolts or metal dowels.
| Size |
Diameter |
Coupling height |
Insert width |
Number of inserts |
Weight |
| |
mm |
mm |
mm |
mm |
gr |
| PM-K-80 |
80 |
32 |
30 |
4 |
65 |
|
|
|
OGNEZA-PM-K Cable penetration, red, d 90 (price on request) [Code number: 1r0125]
Details
|
1r0125 |
|
Application purpose:
- To block the spread of fire along cable lines
- For installation in places of passage of cables, pipelines of engineering systems, technological pipelines
Characteristics:
- due to the fact that the coupling body is detachable, it can be mounted on an already laid cable line;
- metal parts are powder coated to reduce corrosion (colour: red);
- triggers approximately 15 seconds after the temperature rises to +150°C;
- expansion coefficient: not less than 900%;
- the fire resistance limit is 180 minutes;
- service life: 30 years (at temperatures from -50 to +80°C).
Installation recommendations:
- the thickness of the walls where the cable passage is mounted must be at least 150 mm;
- the cable sleeve is installed on both sides in a metal sleeve in the ceiling along the cable lines. If there is no sleeve, installation is possible in a hole sealed with mineral wool;
- fastened with anchor bolts or metal dowels.
| Size |
Diameter |
Coupling height |
Insert width |
Number of inserts |
Weight |
| |
mm |
mm |
mm |
mm |
gr |
| PM-K-90 |
90 |
32 |
30 |
4 |
75 |
|
|
|
OGNEZA Fire collar, lock type "Light", red, d 80 [Code number: 1r0147]
Details
|
1r0147 |
490 rub |
|
|
|
|
OGNEZA Fire collar, lock type "Light", gray, d 65 [Code number: 1r0148]
Details
|
1r0148 |
438 rub |
|
|
|
|
OGNEZA Fire collar, lock type "Light", red, d 65 [Code number: 1r0149]
Details
|
1r0149 |
438 rub |
|
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d32-56 [Code number: 348.200.00.1]
Details
|
348.200.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 40 - 56 |
63 |
7,2 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d63/75 [Code number: 348.201.00.1]
Details
|
348.201.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 63 / 75 |
83 |
9,6 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d90 [Code number: 348.202.00.1]
Details
|
348.202.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 90 |
98 |
11,6 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d110 [Code number: 348.203.00.1]
Details
|
348.203.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 110 |
118 |
13,5 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d125/135 [Code number: 348.204.00.1]
Details
|
348.204.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 125 / 135 |
141 |
15,9 |
10,5 |
7 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d160 [Code number: 348.205.00.1]
Details
|
348.205.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 160 |
168 |
19,6 |
11,5 |
8 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus DIN, d200 [Code number: 348.206.00.1]
Details
|
348.206.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For installation in ceilings and walls with fire resistance F 30 to F 90, partly or completely mortared in place
- For inclined installation in ceilings and walls of fire resistance class F 30 to F 90, partly or completely mortared in place
- For later installation in ceilings and walls with fire resistance class F 30 to F 90
- For protection against the spread of smoke and fire
Characteristics:
- Fire resistance class R 30, R 60 and R 90 in accordance with DIN 4102-11
- Sound-absorbing
- National technical approval no. Z-19.17-1927
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
- Information sign
Material: Stainless steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 200 |
211 |
25,3 |
12,5 |
9 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d40/50/56 [Code number: 348.300.00.1]
Details
|
348.300.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 40 - 56 |
63 |
7,7 |
8,5 |
5 |
|
|
|
([NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d63/75 [Code number: 348.301.00.1]
Details
|
348.301.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 63 / 75 |
83 |
10,2 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d90 [Code number: 348.302.00.1]
Details
|
348.302.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 90 |
98 |
12,4 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d110 [Code number: 348.303.00.1]
Details
|
348.303.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 110 |
118 |
14,6 |
8,5 |
5 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d125/135 [Code number: 348.304.00.1]
Details
|
348.304.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 125 / 135 |
141 |
17,1 |
10,5 |
7 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d160 [Code number: 348.305.00.1]
Details
|
348.305.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 160 |
169 |
20,7 |
11,5 |
8 |
|
|
|
(NO LONGER PRODUCED) - Geberit HDPE Fire protection sleeve RS90 Plus EN, d200 [Code number: 348.306.00.1]
Details
|
348.306.00.1 |
|
ATTENTION! This product is temporarily unavailable for order!
Application purposes:
- For pipe feed-throughs 0°–90° in wall or ceiling
- For discharge pipes with pipe dimensions ø 40–200 mm
- For direct installation in ceilings, drywalls or solid walls in new installations
- For later installation in ceilings, drywalls and solid walls
- For protection against the spread of smoke and fire
- Not suitable for passing other parts or aids through
Characteristics:
- Sound-absorbing
- Approval in accordance with EN
- Fire resistance class S 90, R 90, EI 90
Scope of delivery:
- Concrete screws
- Structure-borne sound insulation
- Adhesive strip
Material: Steel
| d |
d1 |
D |
L |
l1 |
| mm |
mm |
cm |
cm |
cm |
| 200 |
207 |
25,7 |
12,5 |
9 |
|
|
|
Fire protection sleeve Wavin Optima, d 40 [Code number: 4026101 / 3161366]
Details
|
4026101 |
|
ATTENTION! This product is temporarily unavailable for order! Application purposes:
- For domestic drainage systems
Description
Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.
Dimension: d 40 mm
|