Logo
Ru| En
Loading

Connecting and transition elements for sewerage

Photo Name Article Price
Contec Rapid-S-W2 Coupling for SML pipe systems, DN - 125 [Code number: NR-500125]
Details
NR-500125 862 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: stabilized stainless steel W2, 1.4510/11 in accordance with EN 10088
  • Fixing parts: clip 1.4301 or 1.4510/11, bolt, washer and steel square nut with zinc coating lamella type
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
125 149 160 52

Download installation manual of product: Contec Rapid-S-W2 Coupling Contec Rapid-S-W2 Coupling

Contec Rapid-S-W2 Coupling for SML pipe systems, DN - 150 [Code number: NR-500150]
Details
NR-500150 937 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: stabilized stainless steel W2, 1.4510/11 in accordance with EN 10088
  • Fixing parts: clip 1.4301 or 1.4510/11, bolt, washer and steel square nut with zinc coating lamella type
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
150 176 183 52

Download installation manual of product: Contec Rapid-S-W2 Coupling Contec Rapid-S-W2 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 50 [Code number: NR-601050]
Details
NR-601050 1 237 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
50 71 80 46

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 70 [Code number: NR-601070]
Details
NR-601070 1 417 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
70 92 104 46

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 80 [Code number: NR-601080]
Details
NR-601080 1 422 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
80 98 109 46

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 100 [Code number: NR-601100]
Details
NR-601100 1 603 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
100 125 132 46

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 125 [Code number: NR-601125]
Details
NR-601125 2 019 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
125 149 160 52

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

Contec Rapid-W5 Coupling for SML pipe systems, DN - 150 [Code number: NR-601150]
Details
NR-601150 2 624 rub

Purpose of use:

  • For installation of cast-iron non-socket (SML) pipes according to DIN 19522 / EN 877 standards

Characteristics

  • Clamp material: austenitic stainless steel W5, 1.4571 in accordance with EN 10088
  • Fixing parts: austenitic stainless steel 1.4571 in accordance with EN 10088, screw, washer and square nut - steel A4
  • Seal material: ethylene propylene rubber (EPDM)
  • Pressure: up to 0.5 bar
  • Bolt: M8
  • Tightening torque: up to the stop, max. 15 n / m
DN D ≈ H ≈ B ≈
mm mm mm mm
150 176 183 52

Download installation manual of product: Contec Rapid-W5 Coupling Contec Rapid-W5 Coupling

OGRAX-PM fire collar, d 130 (for pipes DN 110) [Code number: pm-110/50]
Details
pm-110/50 384 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
130 50 110
OGRAX-PM fire collar, d 22 (for pipes DN 16) [Code number: pm-16/20]
Details
pm-16/20 320 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
22 20 16
OGRAX-PM fire collar, d 32 (for pipes DN 25) [Code number: pm-25/20]
Details
pm-25/20 320 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
32 20 25
OGRAX-PM fire collar, d 42 (for pipes DN 32) [Code number: pm-32/30]
Details
pm-32/30 336 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
42 30 32
OGRAX-PM fire collar, d 50 (for pipes DN 40) [Code number: pm-40/30]
Details
pm-40/30 336 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
50 30 40
OGRAX-PM fire collar, d 66 (for pipes DN 50) [Code number: pm-50/40]
Details
pm-50/40 368 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
66 40 50
Phoenix PPM Fire collar, d 110 (price on request) [Code number: ppm_110]
Details
ppm_110

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
127 40 DN 110
Phoenix PPM Fire collar Лайт, d 110 (price on request) [Code number: ppm_110_l]
Details
ppm_110_l

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life
  • Light type

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
- - DN 110
Phoenix PPM Fire collar, d 125 (price on request) [Code number: ppm_125]
Details
ppm_125

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
- - DN 125
Phoenix PPM Fire collar, d 16 (price on request) [Code number: ppm_16]
Details
ppm_16

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
29 20 DN 16
Phoenix PPM Fire collar, d 160 (price on request) [Code number: ppm_160]
Details
ppm_160

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
192 80 DN 160
Phoenix PPM Fire collar, d 20 (price on request) [Code number: ppm_20]
Details
ppm_20

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
33 20 DN 20