Logo
Ru| En
Loading

Fire protection couplings

Fire protection coupling – it is a special element of pipeline system which is used for protection the premises against fires. The group of products uncludes the several types of fire protection couplings:

  • PAM-GLOBAL SVB fire protection couplings which are made of chrome steel and intended for cast iron SML pipes;
  • Wavin fire couplings which are suitable for PVC pipes with diameters from 40 to 200 mm;
  • Rehau fire couplings which provide fire resistance limit up to 90 min. The couplings, depending on the type, can consist of a liner made of thermo-expanding material, and a detachable casing or they can consist of two segments combined with straps;
  • Geberit fire protection sleeves – the sleeves are classified as safety class  S 90, R 90, EI 90 and they can have diameter from 32 to 200 mm, and the sleeves. which are suitable only for the Silent-db20 piping system, are suitable for pipes with diameters from 56 to 160 mm.
Photo Name Article Price
Fire protection sleeve Wavin Optima, d 40 [Code number: 4026101 / 3161366]
Details
4026101

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 40 mm

Fire protection sleeve Wavin Optima, d 50 [Code number: 4026102 / 3161374]
Details
4026102

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 50 mm

Fire protection sleeve Wavin Optima, d 63 [Code number: 4026103 / 3161382]
Details
4026103

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 63 mm

Fire protection sleeve Wavin Optima, d 75 [Code number: 4026104 / 3161390]
Details
4026104

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 75 mm

Fire protection sleeve Wavin Optima, d 90 [Code number: 4026105 / 3161404]
Details
4026105

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 90 mm

Fire protection sleeve Wavin Optima, d 110 [Code number: 4026106 / 3161412]
Details
4026106

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 110 mm

Fire protection sleeve Wavin Optima, d 125 [Code number: 4026107 / 3161420]
Details
4026107

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 125 mm

Fire protection sleeve Wavin Optima, d 140 [Code number: 4026108 / 3161439]
Details
4026108

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 140 mm

Fire protection sleeve Wavin Optima, d 160 [Code number: 4026109 / 3161447]
Details
4026109

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 160 mm

Fire protection sleeve Wavin Optima, d 180 [Code number: 4026110 / 3161455]
Details
4026110

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 180 mm

Fire protection sleeve Wavin Optima, d 200 [Code number: 4026111 / 3161463]
Details
4026111

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima double socket coupling is suitable for the installation of internal drainage systems, it is used to prevent the spread of fire in the premises.

Dimension: d 200 mm

OGRAX-PM fire collar, d 130 (for pipes DN 110) [Code number: pm-110/50]
Details
pm-110/50 384 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
130 50 110
OGRAX-PM fire collar, d 22 (for pipes DN 16) [Code number: pm-16/20]
Details
pm-16/20 320 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
22 20 16
OGRAX-PM fire collar, d 32 (for pipes DN 25) [Code number: pm-25/20]
Details
pm-25/20 320 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
32 20 25
OGRAX-PM fire collar, d 42 (for pipes DN 32) [Code number: pm-32/30]
Details
pm-32/30 336 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
42 30 32
OGRAX-PM fire collar, d 50 (for pipes DN 40) [Code number: pm-40/30]
Details
pm-40/30 336 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
50 30 40
OGRAX-PM fire collar, d 66 (for pipes DN 50) [Code number: pm-50/40]
Details
pm-50/40 368 rub

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • case consists of two parts
  • thickness of the OGRAX flame retardant liner is 10 mm
  • keeps operational characteristics at air humidity up to 100% in the temperature range from -50 °C to + 60 °C
  • high fire resistance (more than three parts, EI-180)
  • easy assembly/disassembly
  • no special maintenance
  • moisture resistance
  • durability
  • warranty period of operation - at least 25 years (under conditions precluding corrosion of the metal case)
External diameter Height Pipe diameter
mm mm mm
66 40 50
Phoenix PPM Fire collar, d 110 (price on request) [Code number: ppm_110]
Details
ppm_110

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
127 40 DN 110
Phoenix PPM Fire collar Лайт, d 110 (price on request) [Code number: ppm_110_l]
Details
ppm_110_l

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life
  • Light type

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
- - DN 110
Phoenix PPM Fire collar, d 125 (price on request) [Code number: ppm_125]
Details
ppm_125

Application purposes:

  • For preventing the spread of fire and combustion products through ceilings and walls

Characteristics:

  • Wide size range
  • High fire resistance - EI-180
  • Products are certified
  • The collar operates automatically when the ambient temperature rises
  • Easy assembly/disassembly
  • Moisture resistance
  • Stored at temperatures from -50 °C to +60 °C
  • Long service life

The final price may vary depending on the volume and composition of the order. Request an invoice.

Diameter Height For pipe
mm mm  
- - DN 125