Logo
Ru| En
Loading

Bends for domestic sewerage

Bend for internal sewerage - a shaped part, which is a short pipe, bending at an angle. Bends for internal sewerage allow you to change the direction of the pipeline, as well as mount branching pipelines - for this you can use parallel bends.

The catalog contains products of famous brands:

  • PAM-GLOBAL;
  • Rehau;
  • Geberit;
  • Wavin;
  • Ostendorf;
  • Sinicon;
  • Chemkor.

All bends are available. All goods are certified and meet Russian and European quality and safety requirements.

Photo Name Article Price
WC Special multiple branch PAM-GLOBAL® S, left hand
Details
Nominal internal diameter Range Weight Code number
DN   kg  
100 Left 5,8 155848
Bend PAM-GLOBAL® Plus 88˚ with elongated side 250mm
Details
Nominal internal diameter X1 X2 K Weight Code number
DN mm mm mm kg  
100 250 110 140 3,6 155242
WC Special multiple branch PAM-GLOBAL® S, right hand
Details
Nominal internal diameter Range Weight Code number
DN   kg  
100 Right 6,00 155847
Bend PAM-GLOBAL® S 88˚ with elongated side 250mm
Details
Nominal internal diameter X1 X2 K Weight Code number
DN mm mm mm kg  
70* 250 90 160 2,8 155785
80 250 95 160 2,9 179681
100 250 110 100 3,6 155823

 *Diameter 80 gradually replace diameter 70

Manifold connectors PAM-GLOBAL® S multi-waste
Details
Nominal internal diameter L H W a d e Weight Code number
DN mm mm mm mm mm mm kg  
100 204 125 200 43 142 62 3,2 175626
150 265 165 290 70 184 81 6,1 175629
Double bend PAM-GLOBAL® Plus 88˚
Details
Nominal internal diameter L H W a b c o Weight Code number
DN mm mm mm mm mm mm mm kg  
50 148 148 58 121 50 100 148 1 179343
75 183 183 83 145 60 120 183 1,5 235801
100 228 228 110 170 70 140 228 2,8 155359
150 303 303 160 219 90 180 303 6,3 155422
Bend PAM-GLOBAL® S 88˚ (two joint bends 44˚)
Details

According to DIN 1986, part 1, section 6.1.2, the changes of the direction of main pipelines and sewers may be fulfilled only with using prefabricated pipe bend, and each individual bend can have a maximum angle of 45˚. In some cases, for these purposes can be used two pipe bends 45˚. Due to the double knee one connecting element is saved and the installation becomes easier. In addition, this fitting provides a good opportunity to place the fastening element in its middle. The bend is also intended for use as a transition from the riser to a horizontal pipe, and vice versa.

Nominal internal diameter X1 X2 X3 Weight Code number
DN mm mm mm kg  
50 50 100 121 1,0 155754
70* 60 120 145 1,4 155783
80 60 120 145 1,5 176707
100 70 140 170 3,1 155819
125 80 160 195 4,2 155872
150 90 180 219 7,0 155905

*Diameter 80 gradually replace diameter 70

Bend PAM-GLOBAL® Plus 135˚ for bypass line
Details
Nominal internal diameter X K L Weight Code number
DN mm mm mm kg  
100 312 100 150 5,0 155239
PAM-GLOBAL® S multi-waste sewer collectors
Details
Diameter L H W b d f g h j j k Weight Code number
DN, mm mm mm mm mm mm mm mm mm mm mm mm kg  
100 445 582 445 445 340 45 174 22 165 120 110 12,8 261138
150 445 591 445 445 345 55 181 25 220 170 160 17,3 261434
Circuitous Bend PAM-GLOBAL® S 135˚ for bypass system
Details
Nominal internal diameter X K L Weight Code number
DN mm mm mm kg  
100 312 100 150 5 155818

К - maximum cut length

PAM-GLOBAL® S Single stack branches
Details
Diameter Lateral adjustments L H W O p q Weight Code number
DN   mm mm mm mm mm mm kg  
100 3 consecutive 90° DN100 280 490 230 392 140 281 11,0 177237
100 2 DN100 90° 230 490 230 392 140 281 10,4 177236
100 3 DN100 180° 280 490 180 392 140 281 10,8 177235
PAM-GLOBAL® S Bend 88° with 250 mm calming section
Details
Nominal internal diameter X1 X2 X3 Weight Code number
DN mm mm mm kg  
70 60 301 273 2.8 155784
80 60 301 273 2.9 179679
100 70 312 291 4.8 155820
125 80 322 308 6.1 155873
150 90 334 326 9.6 155906
Bend PAM-GLOBAL® Plus 88˚ (two joint bends 44) and soothing area 250mm
Details
Nominal internal diameter X1 X2 X3 Weight Code number
DN mm mm mm kg  
100 70 312 291 4,8 155240
125 80 322 308 6,1 179341
150 90 334 326 9,6 179342

The bend is used for the transition from the risers to the decelerated areas of the system. According to DIN 1986, Part 1 in respect of risers, which run from 4 to 8 stories or have length from 10 to 22 m, special stowage arrangements are necessary. Transitions in horizontal pipelines, as well as the bend on the sides of the supply and runoff during the joint laying, must be separated by inserting of length of 250 mm.

PAM-GLOBAL® Plus Offset bend 130 mm
Details
Nominal internal diameter X L Weight Code number
DN mm mm kg  
100 70 270 3,7 155241
PAM-GLOBAL® S Offset bends 65, 130, 200 mm
Details
Nominal internal diameter L H W b c Weight Code number
DN mm mm mm mm mm kg  
50 133 185 58 75 35 1.1 156386
75 158 200 83 75 39 1.5 156478
75 233 230 83 150 45 2.3 156482
100 175 205 110 65 70 2 155812
100 185 215 110 75 41 2.5 156596
100 240 270 110 130 70 3.7 155821
100 260 250 110 150 47 3.3 156604
100 310 340 110 200 70 4.2 155822
125 210 236 135 75 46 3.7 156759
125 285 270 135 150 48 4.8 156764
150 235 255 160 75 51 5.1 156853
150 310 300 160 150 56 6.7 156858
200 285 295 210 75 61 8.3 156972
200 360 350 210 150 64 10.8 156976
Long radius bend PAM-GLOBAL® S 88˚
Details
Nominal internal diameter L H W a b Weight Code number
DN mm mm mm mm mm kg  
100 324 324 110 269 230 4,2 156606
150 349 349 160 274 210 8 156860
PAM-GLOBAL® Plus Object connection bend 90° for wash-basins, sinks and urinal units
Details
Nominal internal diameter X1 X2 K1 K2 Weight Code number
DN mm mm mm mm kg  
50 x 50 200 110 120 25 1,4 155205
50 x 60 200 110 120 30 1,6 155206
Vented bend PAM-GLOBAL® S 88˚ radial
Details
Nominal internal diameter L H W p q r Weight Code number
DN mm mm mm mm mm mm kg  
100 166 169 150 95 59 110 2,15 157581
Vented bend PAM-GLOBAL® S 88˚ axial
Details
Nominal internal diameter L H W p q r Weight Code number
DN mm mm mm mm mm mm kg  
100 200 169 110 166 59 110 2,15 156585
Geberit HDPE PVC S-bend, d90/110 [Code number: 388.350.29.1]
Details
388.350.29.1

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For all drainage pipes
  • For converting floor standing WC to wall-hung WC installation

Scope of delivery:

  • Lip seal EPDM
  • Rubber seal EPDM
  • Adhesive PVC-U

Material: PVC

d di H L
mm mm cm cm
90 100 - 105,6 16,7 14,5 - 34,5