Logo
Ru| En
Loading

Sewerage

The company "Inrusstrade" specializes in the supply of high-quality pipeline products for the installation of external and internal sewer systems.

Our catalog contains products of both European and Russian manufacturers from various materials. All offered products are known for their high quality and meet all sanitary requirements.

So, the catalog contains pipes and fittings made of cast iron, polyethylene and polypropylene, steel (chromium, stainless, galvanized).

We offer all the equipment necessary for the installation of sewer systems:

  • pipes and fittings;
  • connecting clamps;
  • brackets;
  • siphons;
  • traps;
  • fire-fighting couplings;
  • instrument pipes;
  • drainage channels etc.

All products are in stock and can be delivered to any region of Russia. For more information, call our managers.

Photo Name Article Price
Base of Wavin Tegra 600, I type, 160 x 30° [Code number: 2001537 / 22986011]
Details
2001537

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Description

Base is used for the installation of the Wavin Tegra 600 drainage chambers. It is intended to connect a shaft pipe which is made of unplasticised PVC. One of design features of the base is that the deflection angle of the socket can be adjusted to 7.5°. The angle of inlet is 30°. It is suitable for smooth-walled pipes. You can see the appearance of base and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Technical characteristics

Material: polyethylene (PE).

Color: black.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

DN α H1 H2 H3 H4 Weight
mm   mm mm mm mm kg
160 30° 646 207 271 168 21,0

Download installation instruction: Chamber Tegra 600

Base of Wavin Tegra 600, I type, 200 x 60° [Code number: 2001538 / 22986022]
Details
2001538

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Description

Base is used for the installation of the Wavin Tegra 600 drainage chambers. It is intended to connect a shaft pipe which is made of unplasticised PVC. One of design features of the base is that the deflection angle of the socket can be adjusted to 7.5°. It is suitable for smooth-walled pipes. The angle of inlet is 60°. You can see the appearance of base and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Technical characteristics

Material: polyethylene (PE).

Color: black.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

DN α H1 H2 H3 H4 Weight
mm   mm mm mm mm kg
200 60° 646 207 274 165 22,0

Download installation instruction: Chamber Tegra 600

Base of Wavin Tegra 600, I type, 250 x 60° [Code number: 2001539 / 22986023]
Details
2001539

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Description

Base is used for the installation of the Wavin Tegra 600 drainage chambers. It is intended to connect a shaft pipe which is made of unplasticised PVC. One of design features of the base is that the deflection angle of the socket can be adjusted to 7.5°. It is suitable for smooth-walled pipes. The angle of inlet is 60°. You can see the appearance of base and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Technical characteristics

Material: polyethylene (PE).

Color: black.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

DN α H1 H2 H3 H4 Weight
mm   mm mm mm mm kg
250 60° 705 207 271 227 23,7

Download installation instruction: Chamber Tegra 600

Base of Wavin Tegra 600, I type, 315 x 60° [Code number: 2001540 / 22986024]
Details
2001540

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Description

Base is used for the installation of the Wavin Tegra 600 drainage chambers. It is intended to connect a shaft pipe which is made of unplasticised PVC. One of design features of the base is that the deflection angle of the socket can be adjusted to 7.5°. It is suitable for smooth-walled pipes. The angle of inlet is 60°. You can see the appearance of base and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Technical characteristics

Material: polyethylene (PE).

Color: black.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

DN α H1 H2 H3 H4 Weight
mm   mm mm mm mm kg
315 60° 705 207 271 227 25,8

Download installation instruction: Chamber Tegra 600

Base of Wavin Tegra 600, I type, 160 x 60° [Code number: 2001541 / 22986021]
Details
2001541

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Description

Base is used for the installation of the Wavin Tegra 600 drainage chambers. It is intended to connect a shaft pipe which is made of unplasticised PVC. One of design features of the base is that the deflection angle of the socket can be adjusted to 7.5°. It is suitable for smooth-walled pipes. The angle of inlet is 60°. You can see the appearance of base and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Technical characteristics

Material: polyethylene (PE).

Color: black.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

DN α H1 H2 H3 H4 Weight
mm   mm mm mm mm kg
160 60° 646 207 271 168 21,0

Download installation instruction: Chamber Tegra 600

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 2, 1000x240x261 - 267 mm (price on request) [Code number: 2002]
Details
2002

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1-19 - channel made of fibre reinforced concrete, loading capacity from A 15 - F 900 acc. EN 1433, CE-conform, with built-in fall 0.5 % with galvanised steel angle housing and boltless quick-locking system SIDE-LOCK, eightfold locking, without crossing bars in the channel line, with safety-joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 260 - 265 77,12 220

Download product data sheet: 2002 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 2

Download the declaration of conformity: 2002 No.105

Download installation example: 2002 Concrete class A 15 - C 250

Download installation example: 2002 Asphalt class D 400 - E 600

Download installation example: 2002 Concrete class D 400 - F 900 in ramps

Download installation example: 2002 Concrete class D 400 - F 900

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Paving class D 400 - E 600 in ramps

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Pavement class D 400 - E 600

Download installation example: 2002 Asphalt class A 15 - E 600 in ramps

Download installation example: 2002 Pavement class A 15 - C 250

Download installation example: 2002 Asphalt class A 15 - E 600

Download installation example: 2002 Concrete class A 15 - D 400 with kerb

Download installation example: 2002 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2002 Pavement class A 15 - C 250

Download installation example: 2002 Concrete class A 15 - C 250

Download installation example: 2002 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2002 Paving class A 15 - C 250 in ramps

Download installation example: 2002 Asphalt class F 9000

Wavin coupling for connection plain end X-Stream pipe to plain end PVC pipe, d - 200-160 [Code number: 2002490 / 23160617]
Details
2002490

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For outdoor sewerage systems

Description

Wavin X-Stream coupling is suitable for installation of outdoor drainage systems. The coupling is designed for connection plain end of X-Stream pipe and fitting to plain end PVC pipe and fitting, for example the pipe and fiting of Wavin MultiLayer system. It is used for connection pipes and fittings with different diameters. You can see the appearance of coupling and its dimensions in the photo and draft.

Wavin X-Stream piping system has the following advantages:

  • Quick installation;
  • Patented connection technology WAVIN "X-S";
  • Low weight of system elements;
  • Durability etc.

Technical characteristics

Material: polypropylene (PP)

Color: black.

Size Dy Du Dy1 L L1
mm mm mm mm mm mm
200/160 225 182 160 217 116
Wavin X-Stream T-piece 45°, equal, d - 200 [Code number: 2002491 / 23160157]
Details
2002491

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For outdoor sewerage systems

Description

Wavin X-Stream T-piece is suitable for installation of outdoor drainage systems. The T-piece is designed for connection pipes and fittings with identical diameter at angle of 45°. You can see the appearance of T-piece and its dimensions in the photo and draft.

Wavin X-Stream piping system has the following advantages:

  • Quick installation;
  • Patented connection technology WAVIN "X-S";
  • Low weight of system elements;
  • Durability etc.

Technical characteristics

Material: polypropylene (PP)

Color: black.

Size Dy Du L L1 Z
mm mm mm mm mm mm
200 225 252 630 126 426
Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 3, 1000x240x267 - 273 mm (price on request) [Code number: 2003]
Details
2003

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1-19 - channel made of fibre reinforced concrete, loading capacity from A 15 - F 900 acc. EN 1433, CE-conform, with built-in fall 0.5 % and galvanised steel angle housing, with boltless quick-locking system SIDE-LOCK, eightfold locking, without crossing bars in the channel line.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 265 - 270 78,03 227

Download product data sheet: 2003 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 3

Download the declaration of conformity: 2003 No.105

Download installation example: 2003 Concrete class A 15 - C 250

Download installation example: 2003 Asphalt class D 400 - E 600

Download installation example: 2003 Concrete class D 400 - F 900 in ramps

Download installation example: 2003 Concrete class D 400 - F 900

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Paving class D 400 - E 600 in ramps

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Pavement class D 400 - E 600

Download installation example: 2003 Asphalt class A 15 - E 600 in ramps

Download installation example: 2003 Pavement class A 15 - C 250

Download installation example: 2003 Asphalt class A 15 - E 600

Download installation example: 2003 Concrete class A 15 - D 400 with kerb

Download installation example: 2003 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2003 Pavement class A 15 - C 250

Download installation example: 2003 Concrete class A 15 - C 250

Download installation example: 2003 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2003 Paving class A 15 - C 250 in ramps

Download installation example: 2003 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 4, 1000x240x273 - 279 mm (price on request) [Code number: 2004]
Details
2004

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.6 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 270 - 275 78,94 235

Download product data sheet: 2004 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 4

Download the declaration of conformity: 2004 No.105

Download installation example: 2004 Concrete class A 15 - C 250

Download installation example: 2004 Asphalt class D 400 - E 600

Download installation example: 2004 Concrete class D 400 - F 900 in ramps

Download installation example: 2004 Concrete class D 400 - F 900

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Paving class D 400 - E 600 in ramps

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Pavement class D 400 - E 600

Download installation example: 2004 Asphalt class A 15 - E 600 in ramps

Download installation example: 2004 Pavement class A 15 - C 250

Download installation example: 2004 Asphalt class A 15 - E 600

Download installation example: 2004 Concrete class A 15 - D 400 with kerb

Download installation example: 2004 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2004 Pavement class A 15 - C 250

Download installation example: 2004 Concrete class A 15 - C 250

Download installation example: 2004 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2004 Paving class A 15 - C 250 in ramps

Download installation example: 2004 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 5, 1000x240x279 - 285 mm (price on request) [Code number: 2005]
Details
2005

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 275 - 280 79,85 242

Download product data sheet: 2005 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 5

Download the declaration of conformity: 2005 No.105

Download installation example: 2005 Concrete class A 15 - C 250

Download installation example: 2005 Asphalt class D 400 - E 600

Download installation example: 2005 Concrete class D 400 - F 900 in ramps

Download installation example: 2005 Concrete class D 400 - F 900

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Paving class D 400 - E 600 in ramps

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Pavement class D 400 - E 600

Download installation example: 2005 Asphalt class A 15 - E 600 in ramps

Download installation example: 2005 Pavement class A 15 - C 250

Download installation example: 2005 Asphalt class A 15 - E 600

Download installation example: 2005 Concrete class A 15 - D 400 with kerb

Download installation example: 2005 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2005 Pavement class A 15 - C 250

Download installation example: 2005 Concrete class A 15 - C 250

Download installation example: 2005 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2005 Paving class A 15 - C 250 in ramps

Download installation example: 2005 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 6, 1000x240x285 - 291 mm (price on request) [Code number: 2006]
Details
2006

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE ­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 280 - 285 80,76 249

Download product data sheet: 2006 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 6

Download the declaration of conformity: 2006 No.105

Download installation example: 2006 Concrete class A 15 - C 250

Download installation example: 2006 Asphalt class D 400 - E 600

Download installation example: 2006 Concrete class D 400 - F 900 in ramps

Download installation example: 2006 Concrete class D 400 - F 900

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Paving class D 400 - E 600 in ramps

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Pavement class D 400 - E 600

Download installation example: 2006 Asphalt class A 15 - E 600 in ramps

Download installation example: 2006 Pavement class A 15 - C 250

Download installation example: 2006 Asphalt class A 15 - E 600

Download installation example: 2006 Concrete class A 15 - D 400 with kerb

Download installation example: 2006 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2006 Pavement class A 15 - C 250

Download installation example: 2006 Concrete class A 15 - C 250

Download installation example: 2006 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2006 Paving class A 15 - C 250 in ramps

Download installation example: 2006 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 7, 1000x240x291 - 297 mm (price on request) [Code number: 2007]
Details
2007

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE ­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 285 - 290 81,67 257

Download product data sheet: 2007 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 7

Download the declaration of conformity: 2007 No.105

Download installation example: 2007 Concrete class A 15 - C 250

Download installation example: 2007 Asphalt class D 400 - E 600

Download installation example: 2007 Concrete class D 400 - F 900 in ramps

Download installation example: 2007 Concrete class D 400 - F 900

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Paving class D 400 - E 600 in ramps

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Pavement class D 400 - E 600

Download installation example: 2007 Asphalt class A 15 - E 600 in ramps

Download installation example: 2007 Pavement class A 15 - C 250

Download installation example: 2007 Asphalt class A 15 - E 600

Download installation example: 2007 Concrete class A 15 - D 400 with kerb

Download installation example: 2007 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2007 Pavement class A 15 - C 250

Download installation example: 2007 Concrete class A 15 - C 250

Download installation example: 2007 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2007 Paving class A 15 - C 250 in ramps

Download installation example: 2007 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 8, 1000x240x297 - 303 mm (price on request) [Code number: 2008]
Details
2008

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­ conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 290 - 295 82,58 264

Download product data sheet: 2008 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 8

Download the declaration of conformity: 2008 No.105

Download installation example: 2008 Concrete class A 15 - C 250

Download installation example: 2008 Asphalt class D 400 - E 600

Download installation example: 2008 Concrete class D 400 - F 900 in ramps

Download installation example: 2008 Concrete class D 400 - F 900

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Paving class D 400 - E 600 in ramps

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Pavement class D 400 - E 600

Download installation example: 2008 Asphalt class A 15 - E 600 in ramps

Download installation example: 2008 Pavement class A 15 - C 250

Download installation example: 2008 Asphalt class A 15 - E 600

Download installation example: 2008 Concrete class A 15 - D 400 with kerb

Download installation example: 2008 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2008 Pavement class A 15 - C 250

Download installation example: 2008 Concrete class A 15 - C 250

Download installation example: 2008 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2008 Paving class A 15 - C 250 in ramps

Download installation example: 2008 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 9, 1000x240x303 - 309 mm (price on request) [Code number: 2009]
Details
2009

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built-in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line, with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 295 - 300 83,49 272

Download product data sheet: 2009 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 9

Download the declaration of conformity: 2009 No.105

Download installation example: 2009 Concrete class A 15 - C 250

Download installation example: 2009 Asphalt class D 400 - E 600

Download installation example: 2009 Concrete class D 400 - F 900 in ramps

Download installation example: 2009 Concrete class D 400 - F 900

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Paving class D 400 - E 600 in ramps

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Pavement class D 400 - E 600

Download installation example: 2009 Asphalt class A 15 - E 600 in ramps

Download installation example: 2009 Pavement class A 15 - C 250

Download installation example: 2009 Asphalt class A 15 - E 600

Download installation example: 2009 Concrete class A 15 - D 400 with kerb

Download installation example: 2009 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2009 Pavement class A 15 - C 250

Download installation example: 2009 Concrete class A 15 - C 250

Download installation example: 2009 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2009 Paving class A 15 - C 250 in ramps

Download installation example: 2009 Asphalt class F 9000

Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.5 %, up to load class F 900, type 10, 1000x240x309 - 315 mm (price on request) [Code number: 2010]
Details
2010

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 300 - 305 85,52 279

Download product data sheet: 2010 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 10

Download the declaration of conformity: 2010 No.105

Download installation example: 2010 Concrete class A 15 - C 250

Download installation example: 2010 Asphalt class D 400 - E 600

Download installation example: 2010 Concrete class D 400 - F 900 in ramps

Download installation example: 2010 Concrete class D 400 - F 900

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Paving class D 400 - E 600 in ramps

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Pavement class D 400 - E 600

Download installation example: 2010 Asphalt class A 15 - E 600 in ramps

Download installation example: 2010 Pavement class A 15 - C 250

Download installation example: 2010 Asphalt class A 15 - E 600

Download installation example: 2010 Concrete class A 15 - D 400 with kerb

Download installation example: 2010 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2010 Pavement class A 15 - C 250

Download installation example: 2010 Concrete class A 15 - C 250

Download installation example: 2010 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2010 Paving class A 15 - C 250 in ramps

Download installation example: 2010 Asphalt class F 9000

Wavin PVC Pressure Pipe systems Threaded pipe cap, PN10, d - 3/8" [Code number: 20101340]
Details
20101340

ATTENTION! This product is temporarily unavailable for order!

PN d B
bar   mm
10 3/8" 13
Wavin PVC Pressure Pipe systems Threaded pipe cap, PN10, d - 1/2" [Code number: 20108340]
Details
20108340

ATTENTION! This product is temporarily unavailable for order!

PN d B
bar   mm
10 1/2" 14
Hauraton FASERFIX SUPER 150 Channel with built-in fall 0.6 %, up to load class F 900, type 11, 1000x240x315 - 321 mm (price on request) [Code number: 2011]
Details
2011

Set of rules:

  • EN 1433

Material:

  • Channel body: FASERFIX fibre-reinforced concrete
  • Angle housing:

Application areas:

  • Motorway, drainage along
  • Motorway service stations
  • Military facilities
  • Bus stations, bus stops
  • Carriageways and roads (along)
  • Fire brigade buildings
  • Airfields, airports
  • Port facilities, container stations
  • Industrial buildings
  • Industrial yards
  • Cable ducts
  • Sewage plants
  • Truck parking areas
  • Exhibition grounds, trade fairs
  • Waste disposal sites
  • Car parking facilities
  • Ramps, Access to underground car parks
  • Truck-Wash facilities
  • Scrap metal yards
  • Haulage companies, loading areas
  • Road verge drainage
  • Filling stations
  • Underground car parks, multi-storey car parks
  • Tunnel drainage
  • Loading and cargo handling yards
  • Access drives private

Product description:

FASERFIX SUPER 150 Type 1­19 ­ channel made of fibre reinforced concrete, loading capacity from A 15 ­ F 900 acc. DIN 19580 / EN 1433, CE­conform, with built­in fall 0.5 %, with galvanised steel angle housing and boltless quick­locking system SIDE­LOCK, eightfold locking, without crossing bars in the channel line,with safety­joint.

Length Width Height Weight Internal channel cross-sect.
mm mm mm kg cm2
1000 240 305 - 310 86,65 285

Download product data sheet: 2011 Hauraton FASERFIX SUPER 150 Channel up to load class F 900, type 11

Download the declaration of conformity: 2011 No.105

Download installation example: 2011 Concrete class A 15 - C 250

Download installation example: 2011 Asphalt class D 400 - E 600

Download installation example: 2011 Concrete class D 400 - F 900 in ramps

Download installation example: 2011 Concrete class D 400 - F 900

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Paving class D 400 - E 600 in ramps

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Pavement class D 400 - E 600

Download installation example: 2011 Asphalt class A 15 - E 600 in ramps

Download installation example: 2011 Pavement class A 15 - C 250

Download installation example: 2011 Asphalt class A 15 - E 600

Download installation example: 2011 Concrete class A 15 - D 400 with kerb

Download installation example: 2011 Asphalted areas class A 15 - D 400 with kerb

Download installation example: 2011 Pavement class A 15 - C 250

Download installation example: 2011 Concrete class A 15 - C 250

Download installation example: 2011 Concrete screed/concrete class A 15 - C 250 in ramps

Download installation example: 2011 Paving class A 15 - C 250 in ramps

Download installation example: 2011 Asphalt class F 9000

Wavin PVC Pressure Pipe systems Threaded pipe cap, PN10, d - 3/4" [Code number: 20118340]
Details
20118340

ATTENTION! This product is temporarily unavailable for order!

PN d B
bar   mm
10 3/4" 16