Logo
Ru| En
Loading

Sewerage

The company "Inrusstrade" specializes in the supply of high-quality pipeline products for the installation of external and internal sewer systems.

Our catalog contains products of both European and Russian manufacturers from various materials. All offered products are known for their high quality and meet all sanitary requirements.

So, the catalog contains pipes and fittings made of cast iron, polyethylene and polypropylene, steel (chromium, stainless, galvanized).

We offer all the equipment necessary for the installation of sewer systems:

  • pipes and fittings;
  • connecting clamps;
  • brackets;
  • siphons;
  • traps;
  • fire-fighting couplings;
  • instrument pipes;
  • drainage channels etc.

All products are in stock and can be delivered to any region of Russia. For more information, call our managers.

Photo Name Article Price
UNIGRIP-KRALLE grip collar for couplings
Details
Nominal internal diameter ≈P ≈D ≈L Pressure (tack ) length Weight Code number
DN mm mm mm bar   kg  
50 22 88 76 10 M8 0,45 221261
70* 22 110 79 10 M8 0,54 221267
80 25 105 78 10 M8 0,53 221268
100 33 145 93 10 M8 0,90 220750
125 32 165 93 10 M8 0,99 221269
150 32 196 102 5 M8 1,23 221270
200 32 252 118 5 M10 1,72 221271
250 38 318 131 3 M10 2,25 227039
300 38 371 131 3 M10 2,50 227040

*Diametr 80 gradually replace diametr 70

Current requirements for connecting reinforcing elements

Installation manual for strengthen connecting element UNIGRIP-KRALLE

PAM-GLOBAL® S Iron flange fitting for roof penetration
Details

To reliable the installation ventilation pipes through the roof, you should use the specially designed element - PAM-GLOBAL® S Iron flange fitting for roof penetration.

Profile seal is inserted between the pipe and flange fitting for roof penetration so that the flange fitting is waterproof. The flange fitting is produced with sealing ring made of EPDM or NBR.

The first flange fitting is installed under the roof insulation layer, and the second flange fitting - above the roof insulation layer. Accordingly the first flange fitting "clamps" еру vapor barrier and the second flange fitting "clamps" waterproofing layer, be it polymer or bituminous.

Nominal internal diameter D d Lk Ø h Weight Code number
DN mm mm mm mm kg  
80 286 135 215 60 6,1 205922
100 324 158 246 60 6,6 205924
125 349 188 271 60 7,5 205925
PAM-GLOBAL® Plus Double branch 45°
Details
Nominal internal diameter X1 X2 X3 L Weight Code number
DN mm mm mm mm kg  
100x100x100 70 190 190 260 4,6 155384
125x125x125 65 240 240 305 7,9 155411
150x150x150 90 265 265 355 11,8 155445
200x200x200 115 340 340 455 18,4 155473
PAM-GLOBAL® S Double branch 45°
Details
Nominal internal diameter X1 X2 X3 L Weight Code number
DN mm mm mm mm kg  
100x100x100 70 190 190 260 5,3 156709
125x100x100 60 220 220 280 6,3 257729
125x125x125 75 230 230 305 7,5 156817
150x100x100 55 225 225 280 7,3 156865
150x150x150 90 270 270 360 12,0 156936
200x200x200 115 340 340 455 18,4 157034
Transitive EPDM-element PAM-GLOBAL®-KONFIX
Details
Nominal internal diameter D1 D DN L1 L Occurrence depth Weight Code number
DN             kg  
50 57 72 40-56 20 58 35 0,11 155759
70/80 77 92 56-75 22 66,5 40 0,20 155790
100 108 126 102-110 27,5 89,5 57 0,30 155833
125 132 151 125 35,5 108,5 65 0,64 155883

Values presented in mm

*Diametr 80 gradually replace diametr 70

Installation manual for connecting element PAM-GLOBAL KONFIX

Wavin Tegra 425 corrugated shaft pipe, length 2 m [Code number: 3011409 / 22978702]
Details
3011409

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For Wavin drainage chambers

Corrugated shaft pipe is used for the installation of Wavin Tegra 600 inspection chambers. The shaft pipe is connected to the base and cone with the help of O-rings. Diameter of the connected pipes must not exceed 160 mm. You can see the appearance of pipe and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Material: polypropylene (PP).

Color: orange.

Working environment: water.

Permissible installation depth: 6 m.

Acceptable groundwater level: 5 m.

Movements of corrugated pipe in ground

Movements of corrugated pipe in ground

Dy/H1 Dy Du L
mm mm mm mm
425 x 2000 425 476 2000
Wavin coupling, d - 145 [Code number: 3045172 / 23753100]
Details
3045172

ATTENTION! This product is temporarily unavailable for order!

Dy L
mm mm
145 170
Wavin Tegra 1000 “In-situ” connector, 200 [Code number: 3064823808 / 22986512]
Details
3064823808

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For pumping station tanks
  • For water chambers
  • For expansion chambers
  • For stormwater and drainage chambers
  • For differential chambers

“In-situ” connector is used for the installation of the Wavin Tegra 1000 drainage chambers and it allows to connect the chamber to a corrugated pipe. You can see the appearance of connector and its dimensions in the photo and draft.

The main advantages of Wavin drainage chambers:

  • Do not require additional anchoring or strengthening procedures;
  • Resistant to loads;
  • Design is adapted to the Russian climate;
  • Suitable for different types of soil.

Material: PVC and rubber.

Working environment: water.

Size Dy Du
mm mm mm
200 200 228

Download installation instruction: 22986512 Chamber Tegra 1000

Wavin air-valve, d 75, 110 [Code number: 4065752 / 24399880]
Details
4065752

ATTENTION! This product is temporarily unavailable for order!

Application purposes:

  • For domestic drainage systems

Description

Wavin Optima air-valve is suitable for the installation of domestic sewerage systems. It is installed for admission air to the sewerage system, so that vacuum in systems without a ventilation outlet to the street do not prevent.

It is not recommended to use the air-valve in the low temperature range, as the valve is not working when the condensate cools in the internal cavity.

Technical characteristics

Material: polypropylene (PP).

Color: white.

Dy F H1 H2
mm mm mm mm
75/110 125 90 135
Hutterer & Lechner Tubular trap with appliance hose connector and ball-joint outlet, DN40x1 1/2' [Code number: HL 100/40]
Details
HL 100/40 2 260 rub

Tubular trap HL 100/40 DN 40 horizontal is made of polypropylene. The device is equipped with ball-joint outlet and appliance hose connector 6/4". In addition, the trap can connect to the washing machine or dishwasher, which uses input 3/4".

Diameter Material Weight
DN, mm   gr
40 polypropylene 260
Hutterer & Lechner Wash-basin trap with rosette, DN32x1 1/4' [Code number: HL 132/30]
Details
HL 132/30 1 672 rub

HL 132/30 wash-basin trap DN32 x 1 1/4' horizontal is connected to a wash basin. It is made of polypropylene and has a weight is 180 grams. The wash-basin trap can connect to a dishwasher or washing machine, height of the dip tube is adjusted. HL 132/30 is equipped with a decorative rosette.

Diameter Material Weight
DN, mm   gr
32 polypropylene 180

Download data sheet: HL 132/30 Wash-basin trap HL 132/30

Hutterer & Lechner Bath tub trap with ball-joint, DN40/50x1 1/2' [Code number: HL 500-6/4]
Details
HL 500-6/4 2 145 rub

Application area:

  • For bath

Characteristics:

  • Material: PP/PE
  • Dimension: DN40/50 x 6/4"
  • Capacity: 0,83 l/s
  • Installation height: 93 mm

Weight: 0,17 kg

 
Packaging data (PE-bag)
Height Width Depth Weight Volume
mm mm mm kg m3
80 100 252 0,176 0,002016000
Hutterer & Lechner Shower block flat 1200 x 256 x 85 mm with horizontal outlet DN50, "Primus" trap, without visible parts [Code number: HL 530F.0]
Details
HL 530F.0 29 291 rub

Shower block HL 530F.0 with horizontal outlet DN50 is intended for near-wall installation. Shower block can use for removing wastewater with temperature to 85 °C. Size of shower block is 256x85x1200 mm. Shower block is equipped with siphone Primus, which is securely "lock" sewer smells. Without visible parts.

Size Diameter Capacity Weight
mm DN, mm l/s gr
256x 85 x 1200 50   1607
 
Material of spare parts
Siphone Shower block
   
polypropylene Grundk. EPS
Hutterer & Lechner Anti-flood valve with electronically controlled flap, additional flap and manual blocking, DN160 [Code number: HL 715.2EPC]
Details
HL715.2EPC 322 112 rub

Application purpose:

  • To reduce the likelihood of flooding basements and semi-basements where there is a risk of reverse current

Characteristics:

  • works in automatic mode;
  • working environment: drains (both non-faecal and faecal) with temperature from 0 to +40°C;
  • working pressure is 0-5 meters of water column;
  • the shutter consists of two chambers, and each has a shutter and an inspection hatch;
  • the first damper located in the direction of movement of the drains is equipped with an electric drive (opening time does not exceed 11 seconds);
  • the damper in the second chamber can be fixed in the closed position manually;
  • there is a backup power supply (working time: up to 168 hours);
  • shutter operation is controlled by an electronic control unit;
  • data on the state of the shutter can be transferred to the dispatching console (there are "dry" contacts for this, switching current 220V / 0.5A);
  • release type: smooth horizontal;
  • mounted with socket pipes made of PP and PVC;
  • power supply: 230V (+10%/-15%), 0.5A, 50Hz;
  • cable length is 6 m.

Attention! The sewer closure must be installed in a non-explosive environment. Also, it cannot be installed in sewer shafts on the street.

Technical characteristics

Diameter Main voltage Weight
DN, mm Volt gr
160 220 7973
 
Material of spare parts
Butterfly nuts Flap Body
     
ABS stainless steel ABS
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 280 635 9,38 0,068453

Documentation

Download data sheet: HL 715.2EPC Anti-flood valve HL 715.2EPC

WC bend 90˚ PAM-GLOBAL® S
Details
Nominal internal diameter X1 X2 X3 X4 Weight Code number
DN mm mm mm mm kg  
80 145 55 50 105 2,0 176725
100 150 44 40 84 2,6 155852
Bend PAM-GLOBAL® S 15˚
Details
Nominal internal diameter X Weight Code number
DN mm kg  
50 40 0,5 155752
70* 45 0,6 155781
80 45 0,7 176702
100 50 1,2 155816
125 60 1,8 155870
150 65 2,4 155903
200 80 4,4 155932

 *Diameter 80 gradually replace diameter 70

68˚ double branch PAM-GLOBAL® S
Details
Nominal internal diameter X1 X2 X3 L Weight Code number Old code number
DN         kg  
50x50x50 60 85 85 145 1,2 156437  
75x75x75 70 110 110 180 2,3 156546  
100x75x75 70 125 115 185 3 156609  
100x100x100 85 130 130 215 3,4 156707 155859
125x100x100 85 145 140 225 4,5 156766 155875
125x125x125 100 155 155 255 5,5 156815  
150x125x125 100 170 165 265 6,6 156867  
150x150x150 115 180 180 295 8,2 156934  
200x150x150 110 210 200 310 10,7 156978  
200x200x200 140 225 225 365 14 157032  

Dimensions are presented in mm

Rectangular access pipe PAM-GLOBAL® S
Details
Nominal internal diameter H G d A F L Weight Code number
DN             kg  
100 83 160 100 200 230 340 7,6 179196
125 101 190 125 225 255 370 10,3 179197
150 112 215 150 250 280 395 14,5 179198
200 137 262 200 300 330 485 22,0 179199
250 170 330 260 350 380 540 38,5 179200
300 195 380 310 400 430 610 50,0 179201

Dimensions are presented in mm

Expansion plug PAM-GLOBAL® S
Details
Code number L Weight Code number
DN mm kg  
50 33 0,2 156374
70* 52 0,4 156468
80 63 0,5 176715
100 55 1,0 156579
125 53 1,3 156747
150 53 2,1 156839
200 63 4,2 156961
250 53 6,2 157060
300 56 9,0 157125

* Diameter 80 gradually replace diameter 70

88˚ single branch PAM-GLOBAL® S with angle of entry 45˚
Details
Nominal internal diameter X1 X2 X3 L Weight Code number
DN         kg  
50x50 79 80 66 145 1,0 155767
70x50* 83 90 72 155 1,3 155787
80x50 85 90 75 160 1,4 176718
70x70* 97 95 83 180 1,7 155804
80x80 95 95 85 180 1,8 176719
100x50 94 105 76 170 2,1 155827
100x70* 102 110 88 190 2,3 155829
100x80 100 110 90 190 2,4 176720
100x100 115 115 105 220 2,7 155855
125x50 98 120 82 180 2,8 155876
125x70* 107 125 93 200 2,9 155878
125x80 105 125 100 205 3,0 176722
125x100 125 130 110 235 4,2 155880
125x125 137 135 123 260 5,0 155894
150x50 100 140 100 200 3,9 155908
150x70* 115 140 100 215 4,4 155909
150x80 115 140 105 220 4,4 176723
150x100 130 145 115 245 4,9 155911
150x125 147 150 128 275 6,1 155913
150x150 158 155 142 300 8,5 155925
200x100 145 175 125 270 8,8 156980
200x200 193 183 172 365 10,4 157024
250x250 240 243 228 455 19,5 157102
300x300 265 265 265 530 35 157165
400x400 370 370 314 684 67 170732

Dimensions are presented in mm

* Diameter 80 gradually replace diameter 70