HL roof outlets can be divided into several types:

  • Roof outlets with horizontal outlet;
  • Roof outlets with vertical outlet;
  • Roof outlets with ball-joint outlet.

All HL roof outlets with vertical outlet can have capacity up to 14.1 l/s. They are connected to pipes with diameters from 75 to 160 mm. HL roof outlets are equipped with leaf strainers, electric heating, crimping flanges and other additional equipment.

HL roof outlets with horizontal outlet can be equipped with various additional equipment. They are mounted on pipes with diameters of 75/100 mm, they are made of PVC or PP. The capacity can reach 7.8 l/s.

HL roof outlets with ball-joint outlet can be mounted in both horizontal and vertical positions. They are suitable for flat roofs of small area. The diameter of the outlet is 50/75 mm. The capacity of the HL roof outlets with ball-joint outlet reaches 1.0 l/s.

This group of products includes spare parts for HL roof outlets:

  • Grate frames;
  • Grates;
  • Flat-roof drain bodies;
  • Adapters etc.
Photo Name Article Price
Hutterer & Lechner Flat-roof drain with PVC collar, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1BP/7]
Details
HL 62.1BP/7 26 489 rub

Flat-roof drain HL 62.1BP/7 is equipped with insulated drain body, PVC collar, cut-to-size grate frame 19 - 68 mm and stainless steel grate 137 x 137 mm. The flat-roof drain has vertical outlet DN75. It weighs 1743 grams. Capacity is 6,00 l/s.

Diameter Capacity Weight
DN, mm l/s gr
75 6,00 1743
 
Material of spare parts
Grate Grate frame Adapter Body
       
stainless steel polypropylene polypropylene polyvinylchloride (PVC)
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,08 0,0266805

Download example of use: HL 62.1BP/7 Flat-roof drain HL 62.1BP/7

Hutterer & Lechner Flat-roof drain with PP-flange and heating (10-30W/230V), vertical, DN110 [Code number: HL 62.1F/1]
Details
HL 62.1F/1 19 432 rub

Flat-roof drain HL 62.1F/1 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN110. The body and leaf catcher are made of polypropylene. It weighs 1426 grams. Capacity is 7,85 l/s. Diameter of the leaf catcher is 180 mm.

Diameter Capacity Weight
DN, mm l/s gr
110 7,85 1426
 
Material of spare parts
Leaf catcher Body
   
polypropylene polypropylene
PP-flange for welding of FPO-sheetings
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 1,5 0,0266805
Hutterer & Lechner Flat-roof drain with PP-flange and heating, without domed plastic grate, vertical, DN110 [Code number: HL 62.1F/1-K]
Details
HL 62.1F/1-K 16 034 rub
Hutterer & Lechner Flat-roof drain with PP-flange and heating, vertical, DN125 [Code number: HL 62.1F/2]
Details
HL 62.1F/2 19 432 rub

Flat-roof drain HL 62.1F/2 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN125. The body and leaf catcher are made of polypropylene. It weighs 1421 grams. Capacity is 10,75 l/s. Diameter of the leaf catcher is 180 mm.

Diameter Capacity Weight
DN, mm l/s gr
125 10,75 1421
 
Material of spare parts
Leaf catcher Body
   
polypropylene polypropylene
PP-flange for welding of FPO-sheetings
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2 0,0266805
Hutterer & Lechner Flat-roof drain with PP-flange and heating (10-30W/230V), vertical, DN75 [Code number: HL 62.1F/7]
Details
HL 62.1F/7 19 432 rub

Flat-roof drain HL 62.1F/7 is equipped with thermal-insulated body, self-control heating, leaf catcher and PP-flange for welding of FPO-sheetings, based on PP. The flat-roof drain has vertical outlet DN75. The body and leaf catcher are made of polypropylene. It weighs 1447 grams. Capacity is 7,4 l/s. Diameter of the leaf catcher is 180 mm.

Diameter Capacity Weight
DN, mm l/s gr
75 7,40 1447
 
Material of spare parts
Leaf catcher Body
   
polypropylene polypropylene
PP-flange for welding of FPO-sheetings
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,48 0,0266805
Hutterer & Lechner Safety roof drain, with PP collar, heating element U=230V, power 10-30W, vertical, DN110 [Code number: HL 62.1FSafe/1]
Details
HL 62.1FSafe/1 36 126 rub

Safety roof drain HL 62.1FSafe/1 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.

Diameter Mounting height Weight
DN, mm mm kg
110 100 3,391
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
4,5 (35 mm) 0,9 3,8 6,4 9,1 12,2 15,8 20,1
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
4,5 (35 mm) 0,9 3,2 5,5 8,1 9,6 10,1 10,5
 
Material of spare parts
Flat grate Roof drain body
   
polypropylene polypropylene
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,391 0,057066625
Hutterer & Lechner Safety roof drain, with PP collar heating element U=230V, power 10-30W, vertical, DN125 [Code number: HL 62.1FSafe/2]
Details
HL 62.1FSafe/2 36 126 rub

Safety roof drain HL 62.1FSafe/2 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.

Diameter Mounting height Weight
DN, mm mm kg
125 100 3,634
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
7,0 (45 mm) 0,9 3,8 6,2 9,1 12,1 15,7 20
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
7,0 (45 mm) 0,9 3,7 6 8,5 11,6 13,9 14,4
 
Material of spare parts
Flat grate Roof drain body
   
polypropylene polypropylene
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,634 0,057066625
Hutterer & Lechner Safety roof drain, with PP collar heating element U=230V, power 10-30W, vertical, DN75 [Code number: HL 62.1FSafe/7]
Details
HL 62.1FSafe/7 36 126 rub

Safety roof drain HL 62.1FSafe/7 is equipped with electric heating. Outlet is vertical. There is a PP collar. Height-adjustable inlet edge from 28 to 68 mm.

Diameter Mounting height Weight
DN, mm mm kg
75 100 3,091
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
1,7 (35 mm) 0,8 3,6 5,9 8,7 12,1 14,8 15
 

The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.

DIN EN 1253 5 mm 15 mm 25 mm 35 mm 45 mm 55 mm 65 mm
               
1,7 (35 mm) 0,8 3,2 5,4 5,4 5,5 5,6 5,7
 
Material of spare parts
Flat grate Roof drain body
   
polypropylene polypropylene
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,091 0,057066625
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN110 [Code number: HL 62.1H/1]
Details
HL 62.1H/1 22 285 rub

Application purpose:

  • For unused roofs
  • For collecting storm and melt water

Characteristics:

  • there is a polymer bitumen sheet with a diameter of 500 mm, welded to the body and pressed with a stainless steel flange;
  • release type: horizontal;
  • it is possible to connect any pipe made of PP or PVC to the outlet (to connect a cast-iron or steel pipe, use the HL9 adapter);
  • for electric heating, a self-regulating electric heating cable is used (power 10-30 W / 220 V) - a waterproofing sleeve or junction box is used to connect it;
  • the length of the electric heating cable is 0.8 m;
  • heat dissipation: 25 W/m;
  • maximum current consumption: 0.16 A;
  • maximum cable temperature: +65°С;
  • funnel can be operated at temperatures from -50°С to +100°С;
  • warranty period: 2 years;
  • service life: 50 years.

Mounting tips:

  • the body is rigidly attached to the supporting structure of the roof, for which the edges of the waterproofing apron are bent to gain access to the mounting holes;
  • using a propane burner, a layer of hydro-vapor barrier (should be on a bitumen basis) is welded with a waterproofing apron of the funnel with an overlap of 100-150 mm.

Technical details

Diameter Capacity Weight
DN, mm l/s gr
110 10,70 1972
 
Material of spare parts
Domed grate Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,4 0,0266805

Documentation

Download example of use: HL 62.1H/1 Flat-roof drain HL 62.1H/1

Hutterer & Lechner Flat-roof drain body with bitumen membrane, heated, vertical, DN110 [Code number: HL 62.1H/1-K]
Details
HL 62.1H/1-K 18 643 rub
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN125 [Code number: HL 62.1H/2]
Details
HL 62.1H/2 22 285 rub

Application purpose:

  • For unused roofs
  • For collecting storm and melt water

Characteristics:

  • there is a polymer bitumen sheet with a diameter of 500 mm, welded to the body and pressed with a stainless steel flange;
  • release type: horizontal;
  • it is possible to connect any pipe made of PP or PVC to the outlet (to connect a cast-iron or steel pipe, use the HL9 adapter);
  • for electric heating, a self-regulating electric heating cable is used (power 10-30 W / 220 V) - a waterproofing sleeve or junction box is used to connect it;
  • the length of the electric heating cable is 0.8 m;
  • heat dissipation: 25 W/m;
  • maximum current consumption: 0.16 A;
  • maximum cable temperature: +65°С;
  • funnel can be operated at temperatures from -50°С to +100°С;
  • warranty period: 2 years;
  • service life: 50 years.

Mounting tips:

  • the body is rigidly attached to the supporting structure of the roof, for which the edges of the waterproofing apron are bent to gain access to the mounting holes;
  • using a propane burner, a layer of hydro-vapor barrier (should be on a bitumen basis) is welded with a waterproofing apron of the funnel with an overlap of 100-150 mm.

Technical details

Diameter Capacity Weight
DN, mm l/s gr
125 14,00 1967
 
Material of spare parts
Domed grate Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,4 0,0266805

Documentation

Download example of use: HL 62.1H/2 Flat-roof drain HL 62.1H/2

Hutterer & Lechner Flat-roof drain with bitumen membrane, heated, vertical, DN160 [Code number: HL 62.1H/5]
Details
HL 62.1H/5 22 285 rub

Application purpose:

  • For unused roofs
  • For collecting storm and melt water

Characteristics:

  • there is a polymer bitumen sheet with a diameter of 500 mm, welded to the body and pressed with a stainless steel flange;
  • release type: horizontal;
  • it is possible to connect any pipe made of PP or PVC to the outlet (to connect a cast-iron or steel pipe, use the HL9 adapter);
  • for electric heating, a self-regulating electric heating cable is used (power 10-30 W / 220 V) - a waterproofing sleeve or junction box is used to connect it;
  • the length of the electric heating cable is 0.8 m;
  • heat dissipation: 25 W/m;
  • maximum current consumption: 0.16 A;
  • maximum cable temperature: +65°С;
  • funnel can be operated at temperatures from -50°С to +100°С;
  • warranty period: 2 years;
  • service life: 50 years.

Mounting tips:

  • the body is rigidly attached to the supporting structure of the roof, for which the edges of the waterproofing apron are bent to gain access to the mounting holes;
  • using a propane burner, a layer of hydro-vapor barrier (should be on a bitumen basis) is welded with a waterproofing apron of the funnel with an overlap of 100-150 mm.

Technical details

Diameter Capacity Weight
DN, mm l/s gr
160 14,10 2001
 
Material of spare parts
Domed grate Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,4 0,0266805

Documentation

Download example of use: HL 62.1H/5 Flat-roof drain HL 62.1H/5

Hutterer & Lechner Flat-roof drain body with bitumen membrane, heated, vertical, DN160 [Code number: HL 62.1H/5-K]
Details
HL 62.1H/5-K 18 643 rub
Hutterer & Lechner Flat-roof drain with bitumen membrane, heated (10-30W/230V), vertical, DN75 [Code number: HL 62.1H/7]
Details
HL 62.1H/7 22 285 rub

Application purpose:

  • For unused roofs
  • For collecting storm and melt water

Characteristics:

  • there is a polymer bitumen sheet with a diameter of 500 mm, welded to the body and pressed with a stainless steel flange;
  • release type: horizontal;
  • it is possible to connect any pipe made of PP or PVC to the outlet (to connect a cast-iron or steel pipe, use the HL9 adapter);
  • for electric heating, a self-regulating electric heating cable is used (power 10-30 W / 220 V) - a waterproofing sleeve or junction box is used to connect it;
  • the length of the electric heating cable is 0.8 m;
  • heat dissipation: 25 W/m;
  • maximum current consumption: 0.16 A;
  • maximum cable temperature: +65°С;
  • funnel can be operated at temperatures from -50°С to +100°С;
  • warranty period: 2 years;
  • service life: 50 years.

Mounting tips:

  • the body is rigidly attached to the supporting structure of the roof, for which the edges of the waterproofing apron are bent to gain access to the mounting holes;
  • using a propane burner, a layer of hydro-vapor barrier (should be on a bitumen basis) is welded with a waterproofing apron of the funnel with an overlap of 100-150 mm.

Technical details

Diameter Capacity Weight
DN, mm l/s gr
75 9,90 1993
 
Material of spare parts
Domed grate Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
180 385 385 2,4 0,033350625

Documentation

Download example of use: HL 62.1H/7 Flat-roof drain HL 62.1H/7

Hutterer & Lechner Flat-roof drain body with bitumen membrane, heated, vertical, DN75 [Code number: HL 62.1H/7-K]
Details
HL 62.1H/7-K 18 643 rub
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar heating element U=230V, power 10-30W, vertical, DN110 [Code number: HL 62.1HSafe/1]
Details
HL 62.1HSafe/1 39 941 rub

Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.

Diameter Mounting height Weight
DN mm mm kg
110 100 3,611

Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m.

Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
4,5 (35 mm) 0,9 3,8 6,4 9,1 12,2 15,8 20,1

Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions.

Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
4,5 (35 mm) 0,9 3,2 5,5 8,1 9,6 10,1 10,5
 
Material of spare parts
Leaf strainer Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,411 0,0444675
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar, heating element U=230V, power 10-30W, vertical, DN125 [Code number: HL 62.1HSafe/2]
Details
HL 62.1HSafe/2 39 941 rub

Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.

Diameter Mounting height Weight
DN mm mm kg
125 100 3,621

Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m.

Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
7,0 (45 mm) 0,9 3,8 6,2 9,1 12,1 15,7 20

Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions.

Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
7,0 (45 mm) 0,9 3,7 6 8,5 11,6 13,9 14,4
 
Material of spare parts
Leaf strainer Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,421 0,0444675
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar, heating element U=230V, power 10-30W, vertical, DN160 [Code number: HL 62.1HSafe/5]
Details
HL 62.1HSafe/5 39 941 rub

Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.

Diameter Mounting height Weight
DN mm mm kg
160 100 3,631

Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m.

Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
8,1 (45 mm) 0,9 3,8 6,5 9,3 12,8 16,5 21,5

Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions.

Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
8,1 (45 mm) 0,9 3,2 5,8 8,1 9,2 10,2 11
 
Material of spare parts
Leaf strainer Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,431 0,0444675
Hutterer & Lechner Safety roof drain, with bitumen membrane, with PP collar heating element U=230V, power 10-30W, vertical, DN75 [Code number: HL 62.1HSafe/7]
Details
HL 62.1HSafe/7 39 941 rub

Safety roof drain with electric heating, with polymer-bitumen cloth, with vertical outlet, with the ability to adjust the thickness of the water layer from 28 to 68 mm.

Diameter Mounting height Weight
DN mm mm kg
75 100 3,371

Capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe with a length of 3 m.

Capacity in l/s at a thickness of a layer of water over a funnel of 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
1,7 (35 mm) 0,8 3,6 5,9 8,7 12,1 14,8 15

Capacity measured in accordance with DIN EN 1253 with a vertical outlet without nozzles and extensions.

Capacity in l/s with the thickness of the water layer above the funnel 5-65 mm.

DIN EN 1253 5 15 25 35 45 55 65
mm mm mm mm mm mm mm mm
1,7 (35 mm) 0,8 3,2 5,4 5,4 5,5 5,6 5,7
 
Material of spare parts
Leaf strainer Body
   
polypropylene polypropylene, bitumen membrane
 
Packaging data (carton)
Height Width Depth Weight Volume
mm mm mm kg m3
385 385 385 4,171 0,0444675
Hutterer & Lechner Flat-roof drain body, vertical, DN110 [Code number: HL 62/1-K]
Details