Diameter | Mounting height | Weight |
---|---|---|
DN, mm | mm | kg |
75 | 150 | 3,371 |
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet pipe length of 3 m. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
DIN EN 1253 | 5 mm | 15 mm | 25 mm | 35 mm | 45 mm | 55 mm | 65 mm | |
---|---|---|---|---|---|---|---|---|
DN75 | 1,7 (35 mm) | 0,7 | 3,9 | 6,1 | 8,8 | 11,1 | 15 | 17,5 |
DN110 | 4,5 (35 mm) | 0,9 | 3,7 | 6,4 | 8,9 | 12,1 | 15,9 | 20,1 |
The capacity is measured in accordance with DIN EN 1253 with a vertical outlet without extensions. The capacity in l/s at thickness water layer above the roof drain is 5-65 mm.
DIN EN 1253 | 5 mm | 15 mm | 25 mm | 35 mm | 45 mm | 55 mm | 65 mm | |
---|---|---|---|---|---|---|---|---|
DN75 | 1,7 (35 mm) | 1,2 | 3,6 | 5,4 | 5,6 | 5,7 | 5,9 | 6 |
DN110 | 4,5 (35 mm) | 0,8 | 3,3 | 4,1 | 4,2 | 4,3 | 4,4 | 4,5 |
Flat grate | Roof drain body |
---|---|
polypropylene | polypropylene, bitumen membrane |
Height | Width | Depth | Weight | Volume |
---|---|---|---|---|
mm | mm | mm | kg | m3 |
300 | 385 | 385 | 4,173 | 0,0444675 |
Hutterer & Lechner Flat grate, d 150mm [Code number: HL 170]
Hutterer & Lechner Reduction, DN75/110 [Code number: HL 0317.4E] (Russia)
Hutterer & Lechner Extension with stainless steel clamping ring, 300 mm / d 125 [Code number: HL 65] (Russia)
Hutterer & Lechner Extension with PP-flange for welding of FPO-sheeting, based on PP, 345mm / d125 [Code number: HL 65F]
Hutterer & Lechner Extension with bitumen membrane d 500 mm, 300 mm / d 125 [Code number: HL 65H]
Hutterer & Lechner Extension with PVC collar, 345 mm / d 125 [Code number: HL 65P]